background image

 

 

- 1 -

 

www.zeeltronic.com 
[email protected] 
 
updated 13.06.2008 
program version: 000.070508 
 

USER MANUAL  

VCDI-30 DIGITAL IGNITION CONTROL UNIT 

 
 

 

TECHNICAL DATA 
 
Limit values: 
- minimum revs 

200 RPM 

- maximum revs 

20000 RPM 

- minimum supply voltage 

8 Volts 

- maximum supply voltage 

20 Volts 

- max. supply voltage for 1 minute 

40 Volts 

- current draw  

                     25 mAmp 

- maximum continuous current for shift light output 

1 Amp  

- peak current for shift light output  

5 Amp 

 
Circuit is protected against reverse supply voltage (wrong connection). 
 
Features: 
- three inputs for magnetic pickups 
- store and load function for 10 ignition curves 
- shift light output 
- external switch for changing ignition curve while riding 
- easy and fast programming on the field, via hand held programmer 
- programming while machine running - you can immediately see effects 
- each curve can be set in 4 to 10 curve points 
- advance/retard whole ignition curve 
- three stage rev limit (retard timing, reduced spark, spark off) 
- signal delay compensation  
- instant monitoring of rev's and angle, via LCD(hand held programmer) 
- fast processing for high accuracy - delays from 1us 
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...)

 

Summary of Contents for VCDI-30

Page 1: ...upply voltage wrong connection Features three inputs for magnetic pickups store and load function for 10 ignition curves shift light output external switch for changing ignition curve while riding easy and fast programming on the field via hand held programmer programming while machine running you can immediately see effects each curve can be set in 4 to 10 curve points advance retard whole igniti...

Page 2: ...d whole ignition curve Rev Limit rev limit Static Angle static angle stator position Compensation signal delay compensation from pickup to spark plug Pulse Width output signal pulse width Shift Light shift light Remote SW activating deactivating external switch Exit 3 LOAD SETTINGS Enter menu and move to Load Settings with pressing or and then press enter Now you can select position number of prev...

Page 3: ...urve point Exit Curve exit submenu Important To avoid wrong processing don t make unreasonable curve course Every time you make any changes to ignition curve it is automatically saved to 0 position Then you can save it to any other position number from 1 to 10 Curve Example with six curve points 5 1 Change NUMBER OF IGNITION CURVE POINTS Move to Nr of Points with pressing or and then press enter N...

Page 4: ...n change rev limit with pressing or in 100 rpm steps and then press enter 8 Set STATIC ANGLE Enter menu and move to Static Angle with pressing or and then press enter Now you can set static angle with pressing or in 0 1deg steps and then press enter More information s about static angle you can find in section 13 9 Set COMPENSATION It is compensation of signal delay from pickup to spark plugs You ...

Page 5: ...ng or in 100 rpm steps and then press enter 12 Set REMOTE SW Enabling or disabling external switch for changing ignition curves while riding Enter menu and move to Remote SW with pressing or and then press enter Now you can enable or disable external switch with pressing or and then press enter 13 MECHANICAL SETTINGS Static Angle Static Angle is ignition advance angle set with stator generator Mea...

Page 6: ...t is not important if motor running or not and if power supply is connected or not Important Do not use too much force when connecting or disconnecting programmer unit 15 ERROR REPORTS Two errors can be displayed Program Memory Error when program memory is corrupted With this error present function of program could be faulty EEPROM Error when eeprom memory is corrupted All programmable data are st...

Reviews: