zeeltronic PSR-S01 User Manual Download Page 2

 

 

- 2 -

1. 

HOW TO ENTER MENU

 

 

PSR 

must be connected to the battery, or engine need to run. Connect 

programmer

 to 

PSR

 

and wait few seconds for activation of 

programmer 

and then press   enter. With pressing  +  

, or  -  you can move through menu and select with pressing  enter  .  
Exit menu with selecting 

Exit.

  

 
 

2. 

MENU ORGANISATION  

 
Load Ign. Curve
 

- load previously saved ignition curve set (from #1 to #2) 

Save Ign. Curve 

- save new ignition curve set (from #1 to #2)

 

 

Ignition Curve 

- ignition curve parameters submenu 

Advance 

 

- advance/retard whole ignition curve 

Rev Limit 

 

- rev limit 

Static Angle   

- static angle (stator position) 

Compensation 

- signal delay compensation (from pickup to spark plug) 

Pulses Per Rev 

- number pulses per rev from pickup  

Exit 

 
 

3. 

LOAD IGN. CURVE 

 
Enter menu and move to 

Load Ign. Curve 

with pressing  +  or  -  and then press  enter  . 

Now you can select position number of previously saved ignition curve set, with pressing  +  
or  -  and then press  enter  . 
 
 

4. 

SAVE IGN. CURVE 

 
Enter menu and move to 

Save Ign. Curve

 with pressing  +  or  -  and then press  enter  . 

Now you can select position number to which you want to save your ignition curve set, with 
pressing  +  or  -  and then press  enter  . 
 

 
5. 

Change IGNITION CURVE 

 
Enter menu and move to 

Ignition Curve 

 with pressing  +  or  -  and then press  enter  . 

Now you are in submenu for setting ignition curve.  
 
Submenu organisation: 

Nr. of Points   

- number of ignition curve points (from 4 to 10) 

1)    

- first ignition curve point 

2)    

- second ignition curve point 

...     ... 
...     ... 

Exit Curve 

 

- exit submenu 

 
Important! 

To avoid wrong processing, don't make unreasonable curve course.  