![zeeltronic PDCI-20V User Manual Download Page 9](http://html1.mh-extra.com/html/zeeltronic/pdci-20v/pdci-20v_user-manual_3273780009.webp)
- 9 -
14.4. POWER JET 1 OFF
TPS
(if TPS enabled)
Enter
Set Ign.
menu and move to
Power Jet 1 OFF
TPS
with pressing + or - and then press
enter .
Now you can change TPS position with pressing + or - (in 1%TPS steps) and then press
enter .
15. SOLENOID
OUTPUT
Enter
Set Ign.
menu and move to
Solenoid Output
with pressing + or - and then press enter .
...you entered submenu for setting
Solenoid Output
parameters.
Submenu organisation:
Output type
- select output type (Power Jet 2, or Duty Solenoid)
Power Jet 2 (if selected)
- set Power Jet 2 parameters
Duty Solenoid (if selected)
- set Duty Solenoid parameters
Exit
- exit submenu
15.1. OUTPUT TYPE
Solenoid output function can be configured as Power Jet 2, or Duty Solenoid. Duty solenoid is
used for adjusting A/F ratio on some carburettors.
Enter
Solenoid Output.
menu and move to
Output type
with pressing + or - and then press
enter .
Now you can change solenoid
Output type
with pressing + or - and then press enter .
15.2. POWER JET 2 (if selected in Output Type menu)
Same settings as
Power Jet 1
...look at section 14.
15.3. DUTY
SOLENOID
(if selected in Output Type menu)
Three duty cycle curves for different throttle positions can be programmed. Each curve can be
programmed in 8 rev points.
Enter
Solenoid Output
menu and move to
Duty
Solenoid
with pressing + or - and then press
enter .
...you enterd submenu for setting
Duty Solenoid
parameters.
Submenu organisation:
Curve 0-33%
- duty cycle curve from 0 to 33% TPS
Curve 34-66%
- duty cycle curve from 34 to 66% TPS
Curve 67-100%
- duty cycle curve from 67 to 100% TPS
Exit
- exit submenu