zeeltronic PDCI-20V User Manual Download Page 9

 

 

- 9 -

14.4.  POWER JET 1 OFF 

TPS 

(if TPS enabled) 

 
Enter 

Set Ign. 

menu and move to 

Power Jet 1 OFF 

TPS

 

with pressing  +  or  -  and then press  

enter  . 

Now you can change TPS position with pressing  +  or  -  (in 1%TPS steps) and then press    

enter  . 

 
 

15. SOLENOID 

OUTPUT 

 
Enter 

Set Ign. 

menu and move to 

Solenoid Output 

with pressing  +  or  -  and then press  enter  . 

...you entered submenu for setting 

Solenoid Output

 parameters. 

 
Submenu organisation: 

Output type  

 

 

 

 

- select output type (Power Jet 2, or Duty Solenoid) 

Power Jet 2 (if selected)

 

 

 

- set Power Jet 2 parameters  

Duty Solenoid (if selected)   

 

- set Duty Solenoid parameters 

Exit    

 

 

 

 

- exit submenu 

 

 
15.1.   OUTPUT TYPE 
 

Solenoid output function can be configured as Power Jet 2, or Duty Solenoid. Duty solenoid is 
used for adjusting A/F ratio on some carburettors.  
 
Enter 

Solenoid Output. 

menu and move to 

Output type 

with pressing  +  or  -  and then press  

enter  . 

Now you can change solenoid 

Output type

 with pressing  +  or  -  and then press enter  . 

 
 
15.2.  POWER JET 2 
(if selected in Output Type menu) 

 
Same settings as 

Power Jet 1

...look at section 14. 

 
 

15.3. DUTY 

SOLENOID 

(if selected in Output Type menu) 

 
Three duty cycle curves for different throttle positions can be programmed. Each curve can be 
programmed in 8 rev points.   
 
Enter 

Solenoid Output

 menu and move to 

Duty

 

Solenoid 

with pressing  +  or  -  and then press  

enter  . 

...you enterd submenu for setting 

Duty Solenoid

 parameters. 

 

Submenu organisation: 

Curve 0-33%   

- duty cycle curve from 0 to 33% TPS 

Curve 34-66% 

- duty cycle curve from 34 to 66% TPS 

Curve 67-100% 

- duty cycle curve from 67 to 100% TPS 

Exit 

 

 

- exit submenu 

 

Summary of Contents for PDCI-20V

Page 1: ...ting spark energy already at 7Volts power supply two isolated input pickup two independent ignition coil outputs individual advance retard of each output store and load function for two ignition maps...

Page 2: ...programmer and then press enter With pressing or you can move through menu and with pressing enter you can choose You can exit menu with choosing Exit 2 MENU ORGANISATION Set Ign set ignition paramete...

Page 3: ...g deactivating external switch for selecting PV curve Exit 3 LOAD IGN MAP Enter Set Ign menu and move to Load Ign Map with pressing or and then press enter Now you can select number of saved ignition...

Page 4: ...s must be programmed for different TPS positions PDCI does not only switch between ignition curves but also interpolate 3D map for all TPS positions above 33 Enter Set Ign menu and move to Set Ignitio...

Page 5: ...NT Move to point you want to change with pressing or and then press enter Now you can change rev point with pressing or in 100 rpm steps and then press enter Now you can change advance angle with pres...

Page 6: ...p is unchanged with setting 0 0deg Enter menu and move to Advance with pressing or and then press enter Now you can set advance with pressing or in 0 1deg steps and then press enter 9 GEAR SHIFT LIGHT...

Page 7: ...tic angle with pressing or in 0 1deg steps and then press enter More information s about static angle you can find in section 31 13 COMPENSATION It is compensation of signal delay from pickup to spark...

Page 8: ...90 TPS Power jet is switched on when revs are between 8000 10000rpm and throttle position is between 70 90 otherwise power jet is switched off 14 1 POWER JET 1 ON RPM Enter Set Ign menu and move to P...

Page 9: ...Jet 2 or Duty Solenoid Duty solenoid is used for adjusting A F ratio on some carburettors Enter Solenoid Output menu and move to Output type with pressing or and then press enter Now you can change s...

Page 10: ...sing enter or exit calibration with pressing Displayed number should be between 0 and 500 18 Set TPS open 100 if TPS enabled For correct operation TPS open position must be calibrated Enter Set Ign me...

Page 11: ...enu and move to Load PV Curve with pressing or and then press enter Now you can select number of PV curve with pressing or and then press enter 23 SAVE PV CURVE Enter Set PV menu and move to Save PV C...

Page 12: ...If deviation is too low then servo motor won t be stabile it will always search for calculated position in small movements Default setting is 5 and should meet in most cases 26 CLOSE POSITION Max clo...

Page 13: ...essing or and then press enter Now you can enable or disable power up test with pressing or and then press enter 30 PV CURVE SW Enabling or disabling PV curve switch for changing PV curves while ridin...

Page 14: ...S position depends on setting in the menu Information You can connect or disconnect PDCI unit from programmer any time you want without any harm It is not important if motor running or not and if powe...

Reviews: