zeeltronic PDCI-20V User Manual Download Page 2

 

 

- 2 -

- store and load function for 5 PV curves 
- external switch for changing PV curve while riding 
- programmable PV deviation 
- programmable max close and max open positions 
- self PV test on power-up 
- PV error detecting (position sensor failure, servo motor failure)  
- fast processing for high accuracy - delays from 1us 
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...)

 

 

Very important! 

Resistor spark plugs must be used, because they produce less electromagnetic disturbances. 
 

Danger of electric shock! 

Avoid connecting PDCI to 12V power supply, before connecting it to ignition coil. High voltage 
is generated and touching free wires can cause electric shock, or damage the unit. 

 
 
1. 

HOW TO ENTER MENU

 

 

PDCI 

must be connected to power supply. Connect 

programmer

 to 

PDCI

 and wait few seconds 

for activation of 

programmer 

and then press   enter. With pressing  +  or  -  you can move 

through menu and with pressing  enter  you can choose.  
You can exit menu with choosing 

Exit.

  

 
 

2. 

MENU ORGANISATION  

 
Set Ign. 

 

- set ignition parameters submenu 

Set PV  

 

- set PV parameters submenu 

Exit 

 
 

2.1. 

SET IGNITION PARAMETERS SUBMENU 

 

 

Load Ign. Map 

- load (select) ignition map (from #1 to #2) 

Save Ign. Map 

- save new ignition map (from #1 to #2)

 

 

Set Ignition Map 

- ignition map parameters submenu 

Advance 

 

- advance/retard whole ignition map on both ignition coil outputs 

Advance 1 

 

- advance/retard ignition coil output 1 

Advance 2 

 

- advance/retard ignition coil output 2 

Gear Shift Light 

- shift light 

Quick Shift 

 

- quick shift settings  

Rev Limit 

 

- rev limit 

Static Angle   

- static angle (stator position) 

Compensation 

- signal delay compensation (from pickup to spark plug) 

Power Jet 1   

- power jet 1 

Solenoid Output 

- solenoid output settings (power jet 2, or duty solenoid) 

TPS

 

 

 

- enable, or disable TPS 

TPS close [0%] 

- calibrating TPS close position  

TPS open [100%]

 

- calibrating TPS open position 

Summary of Contents for PDCI-20V

Page 1: ...ting spark energy already at 7Volts power supply two isolated input pickup two independent ignition coil outputs individual advance retard of each output store and load function for two ignition maps...

Page 2: ...programmer and then press enter With pressing or you can move through menu and with pressing enter you can choose You can exit menu with choosing Exit 2 MENU ORGANISATION Set Ign set ignition paramete...

Page 3: ...g deactivating external switch for selecting PV curve Exit 3 LOAD IGN MAP Enter Set Ign menu and move to Load Ign Map with pressing or and then press enter Now you can select number of saved ignition...

Page 4: ...s must be programmed for different TPS positions PDCI does not only switch between ignition curves but also interpolate 3D map for all TPS positions above 33 Enter Set Ign menu and move to Set Ignitio...

Page 5: ...NT Move to point you want to change with pressing or and then press enter Now you can change rev point with pressing or in 100 rpm steps and then press enter Now you can change advance angle with pres...

Page 6: ...p is unchanged with setting 0 0deg Enter menu and move to Advance with pressing or and then press enter Now you can set advance with pressing or in 0 1deg steps and then press enter 9 GEAR SHIFT LIGHT...

Page 7: ...tic angle with pressing or in 0 1deg steps and then press enter More information s about static angle you can find in section 31 13 COMPENSATION It is compensation of signal delay from pickup to spark...

Page 8: ...90 TPS Power jet is switched on when revs are between 8000 10000rpm and throttle position is between 70 90 otherwise power jet is switched off 14 1 POWER JET 1 ON RPM Enter Set Ign menu and move to P...

Page 9: ...Jet 2 or Duty Solenoid Duty solenoid is used for adjusting A F ratio on some carburettors Enter Solenoid Output menu and move to Output type with pressing or and then press enter Now you can change s...

Page 10: ...sing enter or exit calibration with pressing Displayed number should be between 0 and 500 18 Set TPS open 100 if TPS enabled For correct operation TPS open position must be calibrated Enter Set Ign me...

Page 11: ...enu and move to Load PV Curve with pressing or and then press enter Now you can select number of PV curve with pressing or and then press enter 23 SAVE PV CURVE Enter Set PV menu and move to Save PV C...

Page 12: ...If deviation is too low then servo motor won t be stabile it will always search for calculated position in small movements Default setting is 5 and should meet in most cases 26 CLOSE POSITION Max clo...

Page 13: ...essing or and then press enter Now you can enable or disable power up test with pressing or and then press enter 30 PV CURVE SW Enabling or disabling PV curve switch for changing PV curves while ridin...

Page 14: ...S position depends on setting in the menu Information You can connect or disconnect PDCI unit from programmer any time you want without any harm It is not important if motor running or not and if powe...

Reviews: