Zebra-Tech UW-Caliper Operation Manual 

| 5 | 

4.

 

Operating your UW-Calipers 

Switching On 

Simply press the blue button to switch on your UW-Calipers.  The green 
light will light up briefly and the current caliper measurement will be 
displayed. 

Switching Off 

The calipers automatically switch off if the outer jaw is not moved for        
5 minutes. 

Taking a measurement 

Open the outer jaw of the UW-Caliper wider than the object being 
measured.  Then gently close the jaws on the object.  

The UW-Calipers are calibrated for measuring on a closing jaw action. If 
the jaw movement directly prior to a measurement is in the opening 
direction, then the accuracy of the measurement will be reduced. 

Logging a measurement 

By simply pressing and releasing the blue button, the current caliper 
measurement is logged, together with the current time and date, and the 
water depth if the calipers incorporate the optional pressure sensor. 
 
If your caliper has 2 buttons, whichever button is pressed is logged in the 
data file. This enables measurement differentiation. For example, you can 
differentiate between 2 species, or length and width measurements. 

Summary of Contents for UW-Calipers

Page 1: ...Zebra Tech UW Calipers Operation Manual...

Page 2: ...ing your UW Calipers 5 Switching on 5 Switching off 5 Taking a measurement 5 Logging a measurement 5 Tare the UW Calipers 7 5 Communicating with your UW Calipers 8 Installing UW Caliper software onto...

Page 3: ...rsh environments and underwater to a depth of 40 meters At the push of a button the UW Calipers record the caliper measurement together with the time and date as well as depth if the optional depth se...

Page 4: ...Rugged design Simple to operate even while wearing thick dive gloves One or two button operation Rechargeable on board battery with long operating capacity Capacity to store 8000 records Simple windo...

Page 5: ...l 0 1 meter Memory 8000 records each record consists of Caliper measurement depth if fitted time date Data is non volatile if the battery goes flat data is not lost Battery endurance 40 hours on a ful...

Page 6: ...indicates the battery status is being tested After one minute the green Ready LED will stop flashing while the red Charge LED will remain illuminated When charging is complete the red Charge LED will...

Page 7: ...the object The UW Calipers are calibrated for measuring on a closing jaw action If the jaw movement directly prior to a measurement is in the opening direction then the accuracy of the measurement wi...

Page 8: ...can be created by logging a closed jaw or fully open jaw measurement For example if measurements are being made along a transect a zero measurement can be logged at the end of the transect This can t...

Page 9: ...Calipers When the calipers are gently closed they should display 0 0mm If they don t they can be tarred by pressing and holding the blue button After 10 seconds Tare should appear on the display The b...

Page 10: ...f the software onto the PC The latest version of the software can also be downloaded from the Zebra Tech web site http www zebra tech co nz downloads Connecting the UW Caliper to a computer Unscrew th...

Page 11: ...Zebra Tech UW Caliper Operation Manual 9 UW Caliper Software When the UW Caliper is connected to a PC and the software started the connection window should open...

Page 12: ...cessfully connected the main window opens Auto detect If the UW Calipers have not previously been connected to the computer or the manual connection doesn t find the UW Caliper then the auto detect op...

Page 13: ...n displays the current UW Caliper firmware and software versions Offload Data This button enables stored data to be offloaded from the UW Calipers to the designated file A text box opens enabling comm...

Page 14: ...taken after data has been successfully offloaded from the calipers Set Time date This sets the UW Caliper time and date to PC time and date After communication disconnect the UW Caliper from the coms...

Page 15: ...7 35 40 21 7 8 112 2 22 11 2011 7 35 42 21 7 8 112 2 22 11 2011 7 35 44 21 7 8 112 1 22 11 2011 7 41 02 21 5 7 7 112 2 22 11 2011 7 41 05 21 7 7 112 2 22 11 2011 7 41 07 21 7 7 112 1 22 11 2011 7 41...

Page 16: ...each rod Work the caliper backwards and forwards a few times to distribute the lubricant If fitted the depth sensor may require cleaning If the depth measurement reported rises significantly beyond 0m...

Page 17: ...IGHTEN THE COVER RETAINING SCREWS 8 Further Assistance For further assistance with this or any other Zebra Tech product please contact Zebra Tech Ltd PO Box 1668 Nelson 7040 New Zealand Tel Internatio...