background image

Chinese Post Code Parameters Setting..............32 
UPC/ EAN/ JAN Parameters Setting ..................33 
Coda bar/ Monarch Parameters Setting..............37 
Code 128 Parameters Setting ............................37 
MATRIX 25 Parameters setting ..........................38 
MSI/Plessy parameters setting...........................39 
Italian Pharmacy Parameters Setting .................40 
Barcode Length Setting .....................................41 
ISBN/ ISSN Conversion .....................................42 
Data Editing 
Header and Trailer.............................................43 
Barcode Identifier Code Selection ......................44 
Barcode Identifier Code Setting..........................45 
Truncate Header/Trailer Character .....................47 
Appendixes 
Appendix A 
 Code 39 Full ASCII Code Table..................49 
Appendix B 
 Code 39 Full ASCII Bar Code Table ...........52 
Appendix C 
 Barcode Samples ......................................62 
Appendix D 
 Quick Settings ...........................................63 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ii 

1. INTRODUCTION 
 
Scanning a series of programming bar code labels can 
configure the series scanners.  This allows decoding 
options and interface protocols to be tailored to a 
specific application.  The configuration is stored in 
non-volatile memory and will not be lost by removing 
power from the scanner. 
 

The scanner must be properly powered before 
programming.  For RS-232C type scanners, an external 
power adapter must be used to supply DC power to the 
scanner.  If a keyboard emulation type scanner is used 
with an IBM PC/XT/AT, PS/2 or any fully compatible 
computers, power will be drawn from the keyboard port.  
No external power adapter is required.  If keyboard 
emulation type scanner is used with any other non IBM 
PC compatible computers, an external power adapter 
may be needed. 
 

During the programming mode, the laser scanner will 
acknowledge a good and valid reading with a short beep.  
It will give long beeps for either an invalid or bad 
reading. 
 

2. PROGRAMMING OPTIONS 
 
Programmable options are divided into four groups.  
The first group includes the options that show the 
general behavior of the laser scanner.  The second 
group of options governs the operation of RS-232C type 
serial ports.  The third group selects the keyboard type 
that the keyboard emulation type will be emulated.  The 
last group sets the decoding parameters for each 
barcode symbology. 

 
 
 
 
 
 
 
 

 

Summary of Contents for Z-3080

Page 1: ...Z 3080 CCD Barcode Scanner Multi Interface User s Manual ZBA Inc 94 Old Camplain Road Hillsborough NJ 08844 Phone 908 359 2070 Fax 908 359 1272 Web http www zbausa com...

Page 2: ...mercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio commu...

Page 3: ...f the PC 2 Connect the Scanner cable to the PC 3 Plug the power supply to the scanner 4 Plug the power pack into power source 5 Turn on PC You are ready to use the scanner USB with HID Keyboard Interf...

Page 4: ...16 Baud Rate 16 Data Bit 17 Stop Bit 17 Parity Setting 17 Message Terminator 18 Keyboard Emulation Parameters Setting 19 Keyboard Type Selection 19 Language Selection 21 Message Terminator 22 Function...

Page 5: ...removing power from the scanner The scanner must be properly powered before programming For RS 232C type scanners an external power adapter must be used to supply DC power to the scanner If a keyboard...

Page 6: ...A EAN 13 barcode identifier code F EAN 8 barcode identifier code FF Codabar barcode identifier code N Code 128 barcode identifier code K Code 93 barcode identifier code L MSI barcode identifier code...

Page 7: ...it Disable Chinese Post Length 10 16 digits Code Check digit Transmit Format All Addendum Disable UPC E UPC A Disabled UPC EAN JAN UPC A leading digit Transmit UPC A check digit Transmit UPC E leading...

Page 8: ...label first then scan RESET label ABORT RS 232C PC AT USB WAND EMULATION SHOW VERSION The reading of the ABORT label discards all the parameters read prior to the End of configuration The scanner rema...

Page 9: ...DE SELECTION For CCD scanner The scanner becomes inactive as soon as the data is transmitted It must be triggered to become active again In auto scan mode the scanner is still active after the data is...

Page 10: ...labels can alter the delay time None 10 msec 20 msec 50 msec MESSAGE BLOCK MODE SELECTION This option allows you to treat scanned data as either an independent message or a block message In the messa...

Page 11: ...le Store Set GOOD READ BEEPER TONE SELECTION You can use this option to set frequency and or duration of the buzzer after successful reading Medium Low High Disable 12 SOUND DURATION long 120 ms Mediu...

Page 12: ...G The RS 232C scanner supports four handshaking protocols With these options of communication protocol you can tailor the scanner to meet the requirement of most systems HANDSHAKING PROTOCOL None RTS...

Page 13: ...tart of Configuration ACK NAK RESPONSE TIME SETTING Cont d 3 sec 1 sec 5 sec BAUD RATE 19200 9600 4800 2400 1200 600 16 DATA BIT 7 8 STOP BIT 1 2 PARITY Even Odd Mark Space None End of Configuration 1...

Page 14: ...mulate a number of personal computers keyboard and a number of terminal keyboard Keyboard emulation is activated whenever you have selected the type of keyboard for which the scanner is going to emula...

Page 15: ...3196 Terminal APPLE MAC II IBM 3477 3472 Terminal PS2 30 56 IBM 3477 Terminal Without break code NEC 5200 Note The configuration of the items with asterisk is optional 20 KEYBOARD LANGUAGE SELECTION U...

Page 16: ...nterface for these IBM terminals read the correct key transmission code ON OFF 22 FUNCTION KEY ACTIVE ON OFF FOR IBM AT USE Function keys can be concatenated with input data as header and or trailer S...

Page 17: ...RS SETTING EMULATION SPEED SELECTION Low Medium Normal High Higher 24 EMULATION DATA OUTPUT SELECTION The decoded data output logic level can be set to befit the external decoder Black High Black Low...

Page 18: ...mpatible operating system and USB ports USB compatible operating systems are Windows 98 Windows NT 5 0 and later no additional software is needed since the USB driver support is built into this operat...

Page 19: ...AN Enable UPC EAN JAN Disable ITF 2 of 5 Enable ITF 2 of 5 Disable Chinese Post Code Enable Chinese Post Code Disable Code 128 Enable 28 Code 128 Disable MSI Enable MSI Disable Code 93 Enable Code 93...

Page 20: ...e 39 Full ASCII Code 39 START STOP CHARACTER TRANSMISSION Yes No CHECK DIGIT Calculate and Transmit Calculate but not Transmit 30 NO CONCATENATION Enable Disable INTERLEAVED 2 OF 5 PARAMENTERS SETTING...

Page 21: ...PARAMETERS SETTING LENGTH MAX MIN Set Scan Start of configuration Min 0 4 set max 0 8 set End of configuration 32 CHECK DIGIT NO Calculate and Transmit Calculate but not Transmit UPC EAN JAN PARAMETER...

Page 22: ...8 ADDENDUM NO 5 Characters 2 Characters 2 or 5 Characters FORCE UPC E TO UPC A FORMAT Yes No 34 FORCE UPC A TO EAN 13 FORMAT Yes No TRANSMIT UPC A LEADING CHARACTER Yes No TRANSMIT UPC A CHECK DIGIT...

Page 23: ...CHECK DIGIT Yes No TRANSMIT EAN 8 CHECK DIGIT Yes No 36 CODABAR MONARCH PARAMETERS SETTING START STOP CHARACTER TRANSMISSION No A B C D DC1 DC4 a t b n c d e CONCATENATION Enable Disable CODE 128 PARA...

Page 24: ...elting length 4 to 8 characters MAX MIN Set Scan Start of configuration Min 0 4 set max 0 8 set End of configuration 38 MSI PLESSY PARAMETERS SETTING Examples Felting length 4 to 8 characters MAX MIN...

Page 25: ...ot transmitted CHECK DIGHT No Calculate and Transmit Calculate but not Transmit ITALIAN PHARMACY PARAMETERS SETTING TRANSMIT A CHARACTER Yes No 40 BARCODE LENGTH SETTING CODE 39 LENGTH SETTING MAX MIN...

Page 26: ...of Configuration ISBN ISSN CONVERSION The function convents the UPC EAN codes appearing on books and magazine not ISBN ISSN format ACTIVE ISBN ISSN INACTIVE ISBN ISSN End of Configuration 42 DATA EDIT...

Page 27: ...label to set your choice into memory BARCODE IDENTIFIER CODE SELECTION The series of scanners can transmit max 2 digit barcode identifier code for different types of barcodes Use the labels to choose...

Page 28: ...header or trailer for a symbology When you do the specific character you select is deleted from the symbology you want Truncate header character Truncate trailer character set 1 scan start of con figu...

Page 29: ...2C BS H 08 2D HT I 09 2E LF J 0A 2F VT K 0B 0 0 30 FF L 0C 1 1 31 CR M 0D 2 2 32 SO N 0E 3 3 33 SI O 0F 4 4 34 DLE P 10 5 5 35 DC1 Q 11 6 6 36 DC2 R 12 7 7 37 DC3 S 13 8 8 38 DC4 T 14 9 9 39 NAK U 15...

Page 30: ...u U 75 K 5B v V 76 L 5C w W 77 M 5D x X 78 N 5E y Y 79 _ O 5F z Z 7A W 60 P 7B a A 61 Q 7C b B 62 R 7D c C 63 S 7E d D 64 DEL T 7F 50 APPENDIX A FUNCTION KEY EMULATION FUNCTION KEY ASCII CODE 39 FUNC...

Page 31: ...ation NUL ENQ Up SOH Ins ACK Down STX Del BEL Left ETX Home BS Backspace EOT End HT TAB 52 APPENDIX B CODE 39 FULL ASCII BARCODE TABLE LF Enter num DLE 5 num VT Right DC1 F1 FF PgUp DC2 F2 CR Enter DC...

Page 32: ...CODE 39 FULL ASCII BARCODE TABLE Start of Configuration SYN F6 GS ESC ETB F7 RS Ctl L CAN F8 US Alt L EM F9 SP SUB F10 ESC F11 FS F12 54 APPENDIX B CODE 39 FULL ASCII BARCODE TABLE 0 1 End of Configu...

Page 33: ...APPENDIX B CODE 39 FULL ASCII BARCODE TABLE Start of Configuration 2 3 4 5 6 7 8 9 A 56 APPENDIX B CODE 39 FULL ASCII BARCODE TABLE B I C J D K E L F M G N H O End of Configuration 57...

Page 34: ...APPENDIX B CODE 39 FULL ASCII BARCODE TABLE Start of Configuration P W Q X R Y S Z T U V 58 APPENDIX B CODE 39 FULL ASCII BARCODE TABLE e _ f g a h b i c j d k End of Configuration 59...

Page 35: ...APPENDIX B CODE 39 FULL ASCII BARCODE TABLE Start of Configuration l s m t n u o v p w q x r y 60 APPENDIX B CODE 39 FULL ASCII BARCODE TABLE z DEL End of Configuration 61...

Page 36: ...da bar NW 7 A 9 9 9 5 A UPC A 0 4 42 52 30 24 5 1 EAN 13 4 7 1 12 3 4 5 6 78 9 9 62 APPENDIX D QUICK SETTINGS 1 Quick Settings for Keyboard Wedge Mode Program Reset PC AT End 2 Quick Settings for RS 2...

Reviews: