background image

 

 

ZBA Inc

.

 

Page 6  of 33  

 

1.3. Device Outline  

 

Figure 1: Pocket-Sized P

ersonal Data Collector  

 

1.4. Battery Care  

 

In the interests of providing the best product performance possible, the Personal 

Data Collector comes with high quality, rechargeable Nickel Metal Hydride 

(NiMH) batteries and a Power Adapter. After NiMH batteries are installed, 

Summary of Contents for Z-1070

Page 1: ...made to assure accuracy and completeness we can not be held liable for any errors contained herein or incidental or consequential damages in connection with furnishing performance or use of this mater...

Page 2: ...than 3 9 W radiated power as observed through a 7mm aperture and averaged over 10 seconds Do not attempt to remove the protective housing of the scanner as un scanned laser light with a peak output u...

Page 3: ...h Dongle 11 1 6 1 Software Installation 11 1 6 2 Bluetooth Device Address 11 1 6 4 Pairing and Connect to a SPP Slave PDC 12 2 Getting Started 14 2 1 Installing Batteries 14 2 2 Charging Batteries 14...

Page 4: ...retain more than 2000 UPC records including a timestamp The Personal Data Collector comes with built in data collection firmware called FREETASK which can scan store barcodes and do simple edits on t...

Page 5: ...nd download 3 ea AAA NiMH rechargeable batteries 1 ea Power Adapter 1 ea CD ROM support disk If any package contents are damaged or missing please contact your dealer immediately Optional Accessory Bl...

Page 6: ...ersonal Data Collector 1 4 Battery Care In the interests of providing the best product performance possible the Personal Data Collector comes with high quality rechargeable Nickel Metal Hydride NiMH b...

Page 7: ...It is not good practice to mix new and old batteries Note 1 The PDC comes with 3 AAA 700mAH NiMH rechargeable batteries Use ZBA supplied rechargeable batteries only 2 If the PDC remains unused for an...

Page 8: ...as a validation password 1 5 4 Pairing PDC as SPP Master When a pairing process is initiated by the PDC the PDC is known as the SPP Master The PDC has to know the BD address of a target device to esta...

Page 9: ...ndicates non acknowledged which corresponds to the fact that data was received but it cannot be recognized The data protocol is backed by the use of STX and ETX A data checksum is used to verify if da...

Page 10: ...the result is over 07FH ASCII extend subtract the result by 080H if the result is less than 020H ASCII control code add 020H to the result This will make sure that the checksum will be in the range of...

Page 11: ...port the dongle should detect the system and the Bluetooth icon will turn blue 1 6 2 Bluetooth Device Address Double click the Bluetooth icon to open BlueSoleil s main window Place the mouse cursor o...

Page 12: ...with the PC by WinTaskGen software or Upload mode Please refer to section Use Windows Task Generator and Upload Data 1 6 4 Pairing and Connect to a SPP Slave PDC To pair and connect a SPP slave PDC th...

Page 13: ...etooth passkey window will pop out Type the PIN code as passkey to finish the pair Right click PDC icon and select connect to Bluetooth Serial Port Service A Quick Connect window will pop out after a...

Page 14: ...Charging Batteries Warning Use the Power Adapter with NiMH batteries ONLY Connecting the Power Adapter with any other type of batteries in the PDC voids the warranty damages batteries can burn up the...

Page 15: ...ries are fully charged Charging takes 3 to 5 hours Figure 3 Connecting the Power Adapter It is normal that the Power Adapter and the NiMH battery cells become warm during charging Note If needed when...

Page 16: ...to Remote Screen Figure 5 Remote Screen Then press SCAN to the Main Menu Figure 6 Main Menu 2 4 Menu Operation The menu items show on the LCD in reverse format indicates the current selection Use and...

Page 17: ...e Aim the PDC at the targeted barcode It is good practice to slowly sweep the red light vertically across the barcode Correct wrong Upon a successful decode the PDC will emit a short beeping sound and...

Page 18: ...ta press the key Mode One Press key once start edit numeric Cursor digit add by one each key Press v to move cursor right 1 digit Empty digit cause cursor back to start Press Scan key to confirm input...

Page 19: ...ed data Press v key in input mode to start view Use key move to previous record Use v keys move to next record Use Scan key edit field data FN to exit Use Scan v key for 2 seconds to delete record dat...

Page 20: ...nd Y yes or N no to delete data Follow by SCAN key to confirm Figure 9 Delete Data Use v and keys to adjust the LCD contrast from 1 to 22 Follow by SCAN to confirm 2 10 Power Off Device 1 To turn off...

Page 21: ...ck Set Date Set Time Use and v key 3 4 Barcode Setup Use SCAN key to confirm setting and to go through different types of barcode EAN UPC Code 39 Codabar ITF 25 Code 128 Code 93 RSS14 RSS14 Expanded R...

Page 22: ...ce Select 1 Master Mode Previously paired BD is shown Modify existing BD Press key to modify BD at Edit mode Hexadecimal character v move cursor FN undo all SCAN confirm Press SCAN to confirm again or...

Page 23: ...key to modify existing PIN v key to clear existing PIN SCAN key for scanning a new PIN Followed by SCAN to confirm Pairing to Slave Device BD and PIN are shown Press SCAN to confirm Press SCAN to star...

Page 24: ...2 Cable Disable Enable Sequential Num Press SCAN to select Disable Enable Checksum Digit Press SCAN to select Disable Enable STX ETX Packet Press SCAN to Select If enable STX ETX you will asked set Ad...

Page 25: ...CAN to select 3 5 5 USB HID Cable Select USB HID Cable Set HID Language Press SCAN to select Set Delay Setup numbers and letters v move cursor FN undo SCAN confirm Set Data Terminator Press SCAN to se...

Page 26: ...red whenever performing the User reset operation The Comm Device parameter will not be changed by the reset operation and the parameter tables are different according to different communication device...

Page 27: ...ACK NAK on only Online Send Rec Disable Offline Operate Disable Online enable only RS 232 Cable Sequential Num Disable Checksum Digit Disable STX ETX Packet Disable Add Terminator Disable STX ETX on...

Page 28: ...n the user reset screen will appear Press SCAN key to confirm reset 4 Use Windows Task Generator Before using WinTaskGen for communication power on the PDC and press FN to enter the Remote Screen Pres...

Page 29: ...A Inc Page 29 of 33 3 Press OK to confirm 4 Click Remote Device Setting at the menu bar Another setting window pops up In this window you can remotely change PDC settings Press OK to confirm any chang...

Page 30: ...ZBA Inc Page 30 of 33 5 Click Upload Data...

Page 31: ...ect the PC with the PDC 7 Once connected the numbers of Records and Fields inside the PDC are shown on the left top If Upload Delete Data is selected those stored data will be deleted soon after uploa...

Page 32: ...ZBA Inc Page 32 of 33 8 When uploading is completed all data will be displayed in the main window and Upload Finished pops up...

Page 33: ...e g acetone benzene ether or any kind of phenol based agents on the housing or window solvents may damage the housing finish and the window 5 2 Inspecting on Interface Cables Regularly inspect the int...

Reviews: