1. Insert the supplied rechargeable battery pack into the battery compartment. Note the two exposed

terminals on battery pack should come into contact with the battery spring  22 .

2. Put back the battery cover, with the handset remain switched off, place it into the charger stand.

3. Plug in the supplied AC adapter into an AC outlet and connect its output plug to the DC jack

28  located at the back of charger stand.

4. The charging  25  and full charge  26  indicators should flash red and green alternately while

the battery status is being detected. After a short while, the charging indicator  25  should flash

red only, showing the battery is under fast charging. During charging, the icon          will show

up in LCD and the segments inside the icon will flash in turn.

5. The battery pack should be fully charged up within 4 hours when used for the first time. The

full charge indicator  26  will show steady green. The icon          will disappear or remain shown

up in LCD if unit is switched on.

6. Now the unit can be switched on and ready for operation. Either take out the unit or keep placing

it in the charger stand will cause no damage to the battery. In the latter case, when the battery

is being consumed and voltage falls to a certain level, the charger stand will automatically charge

up the battery. The segments inside the icon          will flash in turn whenever the unit is under

charging.

CAUTION: BE SURE THE BATTERY IN THE HANDSET IS A RECHARGEABLE TYPE BEFORE

YOU PLACE IT IN THE CHARGER STAND, OTHERWISE EXPLOSION MAY RESULT.

Programming Caller Unit and Handset

Range can be tested using the batteries before final mounting and mains connection of the intercom.

Ensure that handsets are fully charged and new batteries are inserted into the caller unit when

programming and doing range tests.

Programming is necessary to avoid false operation made by other nearby wireless intercom systems

which are set to the same channel as yours. Each intercom system is allocated with a unique ID code,

only handsets and caller units which have the same code can communicate with each other. There

are over 65,000 different code combinations and so the chance that you and your neighbours’

system having the same code is extremely low.

N.B.

 To perform pairing process, it is necessary to use alkaline batteries as the AC/DC power supply

in the caller unit should be cut off temporarily while programming.

Summary of Contents for ZA-601

Page 1: ......

Page 2: ......

Page 3: ...by yourself Please read this manual carefully to obtain optimum performance and extended service life from the system For any queries please contact Zartek via email info zartek co za Features Digital...

Page 4: ...button 13 Volume down button 14 Door chime melody select button 22 Battery contact spring 23 Battery cover lock button 24 Charger contact plates 25 Charging indicator 26 Full charge indicator 27 Charg...

Page 5: ...elf battery low M Battery level Volume door chime loudness Status Icon Status A Frontgate doorbell ringing B Backgate doorbell ringing C Missed call Frontgate Backgate D Conversation mode F Door chime...

Page 6: ...er Unit e Rechargeable Ni MH battery pack h Screws and rivets c Charger stand f Mounting bracket i Instruction manual a b d c e f g h i Setting the operating channel Outdoor Caller Unit CALL CH C Outd...

Page 7: ...With the help of a pointed object set the position of the white colour dip switches 6 to one of the following 1 and 2 ON for CH 1 1 OFF and 2 ON for CH 2 1 ON and 2 OFF for CH 3 1 and 2 OFF for CH 4...

Page 8: ...rm channel selection Selected handset channel must correspond to operating channel on the gate station Handset 1 Remove the battery cover by pressing down the lock button 23 2 With the help of a point...

Page 9: ...gets dark the name plate will be automatically illuminated if a AC DC supply is connected although not with a battery supply only Battery supply Insert four AA alkaline cells into battery compartment...

Page 10: ...rger stand will cause no damage to the battery In the latter case when the battery is being consumed and voltage falls to a certain level the charger stand will automatically charge up the battery The...

Page 11: ...n Pairing the Handset and Caller unit Handset Caller unit 9 8 7 CALL OFF ON CHANNEL NORMAL PAIRING 1 2 3 Step 2 Step 3 CALL CALL 2 2 1 Insert four UM 3 alkaline cells into battery compartment Observe...

Page 12: ...e above If programming a four button caller unit be sure to press the appropriate button see above that corresponds to the channel on the handset as all channels are already allocated to buttons Set d...

Page 13: ...handset or caller unit for backgate use it is necessary to perform the cloning process or otherwise the new units will not work with your original system Handset Cloning procedures Ensure that the ha...

Page 14: ...te with the original channel the handset s channel will need to be changed Programming the Back Gate By default all caller units are front gate caller units station A An internal modification is neede...

Page 15: ...LL button 10 icon E appears in LCD The stored ID code will be transmitted and two di sound will be heard periodically CALL 10 Di Di CH C Outdoor CALL 8 CH C Outdoor 7 OFF ON CHANNEL NORMAL PAIRING 1 2...

Page 16: ...ber to set the yellow dip switch 7 back to NORMAL position after pairing or cloning procedures otherwise the caller unit will not operate properly Gate opening AC or DC voltage of 8 12V is needed in o...

Page 17: ...ds to the power slots at the back of the caller unit There is no required polarity for the AC connections Procedure 1 Insert 4 AA batteries not included into the battery slots The LED indicator 2 shou...

Page 18: ...is also needed a relay board GE 247 which does have a specific DC polarity requirement will interface to the gate controller Please see the diagrams below for the 2 options to connect using DC power...

Page 19: ...e unlock round button 11 on the handset once the channel is open The LED light on the relay board will light up when the gate motor is triggered Option B Procedure 1 Connect pin 1 on caller unit to 12...

Page 20: ...gate purchased optionally caller units are installed Wrong setting may lead to false alarm of out of range alert Making receiving calls Make sure there is power supply to the caller unit either by 8 1...

Page 21: ...units will ring and can answer to the call However only the unit who first press the button 9 can reply to the call all others will be excluded from the intercom Handsets under intercom may not be ab...

Page 22: ...an stop the alarm but the icon J or icon K still remains until new batteries are installed The outdoor temperature indication provides you with an idea about the weather which is useful if you plan to...

Page 23: ...y is available c Make proper connection Cannot perform intercom between Handsets a The ID code is not properly cloned to the slave units b Battery has run down c Operate on different channel a Perform...

Page 24: ...his manual can be helpful in drilling the correct position of holes 6 Align the two rivets on the mounting bracket with the holes of the metal hangers on the back of the caller unit make contact and s...

Reviews: