7. Maintenance and servicing

7.1

Cleaning

•  Clean the pole access ladder with a solution of water and a standard cleaning agent.

W

ARNING

D

ANGER

 

OF

 

SLIPPING

 

ON

 

WATER

 

IN

 

THE

 

WORKING

 

AREA

!

>  Dry standing surfaces and holding devices thoroughly after cleaning.

N

OTE

D

ANGER

 

OF

 

ENVIRONMENTAL

 

DAMAGE

!

>  Cleaning agents must not be allowed to seep into the soil!
>  Dispose of used cleaning solutions in accordance with the applicable environmental 

regulations!

7.2

Inspection

Pole access ladders must be regularly inspected by a technical expert to ensure that 
they are safe to use. Regularly means that the inspection intervals must be selected to 
suit the operating conditions.

In the case of continuous and intensive use, daily inspection of the ladders may be 
necessary. If the ladders are seldom used and loads are light, inspection must be 
performed at least once a year.

The technical expert is authorised to carry out inspection by the operator and must have 
attended the seminars prescribed by law in the country concerned. 

• Following 

successful 

inspection, the ZARGES inspection plate (Order No. 891209 

or 828384) must be attached to the product. The month and year in which the next 
inspection is due must be clearly legible for users of the equipment.

Inspection must cover the following points

7.2.1 Deformation, denting and cracks

Check the following components for deformation, denting and cracks:

•  ladders and rails, karabiners, lugs

>  If any component is found to be faulty, the pole access ladder must not be used.
>  If a fall has occurred, the ladder segment in question must always be replaced.

7.2.2 Correct functioning

Before using the pole access ladder, check the following components for correct 
functioning:

•  karabiners, safety fasteners, fall protection, overrun, locking mechanisms

>  If any component is found to be faulty, the pole access ladder must not be used.

Inspect the ZAST-OPTIFLEX-R4 safety slide mechanism in accordance with the 
ZAST-OPTIFLEX-R4 operating instructions.

7.3

Repairs

Effecting repairs of any kind to the equipment is prohibited. Any damaged parts must be 
replaced.

7.4

Spare parts

Each product produced to customer specifications is assigned a serial number. The 
serial number can be found on the type plate. This serial number can be used to order 
appropriate spare parts.

Use only original spare parts manufactured by ZARGES.

Summary of Contents for Skymaste Industrial Z600

Page 1: ...29860 Pole Access Ladder en Z600...

Page 2: ...2 english 3 11...

Page 3: ...ns 5 2 4 Safety instructions for working with electrical equipment 6 3 Technical description 7 3 1 Scope of delivery 7 3 2 Identification 7 3 3 Technical data 7 4 Assembly 8 4 1 Safety instructions fo...

Page 4: ...isregarding these warnings may lead to injury or even fatal injury NOTE The word Note warns of the danger of damage to property or the environment Failure to observe these warnings may lead to damage...

Page 5: ...ccess ladder use in winds of strengths in excess of 12 m s storms and thunderstorms unauthorised modifications or repairs to the pole access ladder use of non original spare parts climbing the pole ac...

Page 6: ...ed in the vicinity of such units if the following conditions are met The unit must be disconnected and secured against being switched back on The section of the unit in question must be de energised T...

Page 7: ...ied see the type plate The type plates are attached to the ladder stiles 3 3 Technical data The maximum height and weight vary according to the scope of the order See the order confirmation for custom...

Page 8: ...5 1 1 General safety instructions on use Before using the product check the following Have all parts included in the scope of delivery been fitted Is the pole access ladder standing in vertical posit...

Page 9: ...ty device when exiting the system at the top end of the ladder 5 2 Use 6 Dismantling storage and transport 6 1 Dismantling To dismantle the product follow the instructions for assembly in reverse orde...

Page 10: ...n plate Order No 891209 or 828384 must be attached to the product The month and year in which the next inspection is due must be clearly legible for users of the equipment Inspection must cover the fo...

Page 11: ...11 2 2 1 1 1 A 41916 Aufbau...

Page 12: ...12 2 2 1 2 LCS 1 1 2 2 optional safety measures...

Page 13: ...13 3 1 ZAST OPTIFLEX R4 4 1 2 B A B 41917...

Page 14: ...14 5 1 2 2 1 3 2 1 B B...

Page 15: ...15 6 1 ZAST OPTIFLEX R4 7 1 2 B C C 41918...

Page 16: ...16 8 1 2 C C 1 2 9 ZAST OPTIFLEX R4 1 2 3...

Page 17: ...17 Max 150 kg Verwenden...

Page 18: ...ZARGES GmbH Postfach 16 30 82360 Weilheim Tel 49 8 81 68 71 00 Fax 49 8 81 68 75 00 E Mail zarges zarges de Internet http www zarges de 2010 by Zarges GmbH 05 2010...

Reviews: