Handling Instructions

 

• Ensure that the mains plug is disconnected prior to moving the product.
• Do not damage the cables by bending it excessively or placing a heavy object on top.
• The product shall be handled according to the illustration below.

Summary of Contents for ZapCharger Portable C1

Page 1: ...ZapCharger Portable C1 BRUKERMANUAL USER MANUAL...

Page 2: ...transformator er opptil 10 ganger lettere og mer kompakt enn en tradisjonell transformator Den opererer p en mye h yere frekvens ved benytte banebrytende teknologi basert p silisiumkarbid Beskyttelse...

Page 3: ...Anvisninger for sikker bruk 5 ZapCharger Portable 6 Statusindikatorer p beskyttelsesenheten 6 Tilkobling av beskyttelsesenhet 7 Koble fra beskyttelsesenheten 7 Starte lading 8 Feils king 8 Oppbevaring...

Page 4: ...lingen ikke pnes Ikke bruk skj teledning St pselet skal bare settes rett inn i en fastmontert husholdningskontakt For forhindre brann skal produktet ikke brukes i et gammelt ledningsnett av ukjent kva...

Page 5: ...er bruk P se at st pselet er koblet fra vegguttaket f r produktet forflyttes Ikke plassere tunge objekter p kablene og unng at de blir utsatt for overdrevet b ying Produktet skal h ndteres i henhold t...

Page 6: ...Legrand Green Up Schuko CEE 7 7 Lysindikator ZapCharger Portable Statusindikatorer p beskyttelsesenheten BL R D GUL GR NN IEC 62196 2 Type 2 Male Plugg til Beskyt telsesenheten 607 cm 157 cm 17cm Ladi...

Page 7: ...godt festet ved at kontaktl sen er festet i l sesporet Koble fra beskyttelsesenheten 1 Trykk inn kontaktl sen for l se ut isolasjonsenhetens plug fra beskyttelsesenheten 2 Dra ut pluggen fra beskyttel...

Page 8: ...taket Feils king F lg trinnene under hvis produktet ikke starter hvis den r de lampen lyser eller hvis det elektrisk kj ret yet ikke begynner lade 1 Fjern EV pluggen fra det elektriske kj ret yet 2 Ti...

Page 9: ...oblet henholdsvis kj ret yet og vegguttaket 2 Plasser isolasjonsenheten vannrett p en jevn overflate med naturlig drenering 3 Hell en jevn str m av rent ferskvann inn i lufteinntaket inntil det vannet...

Page 10: ...Type 2 Male Maks 16A Maks 3 6kW Legrand Green Up Maks 14A Maks 3 2kW Schuko CEE 7 7 Maks 10A Maks 2 3kW Topologi IT TN TT Elektrisk beskyttelse Sikringer Redundant RCD Generelt Tilf rselspenning 230V...

Page 11: ...state transformer is up to 10 times lighter and more compact than a traditional transformer It operates at a much higher frequency using state of the art Silicon Carbide technology The Protection Uni...

Page 12: ...g Instructions 14 ZapCharger Portable 15 Status Indicators on the Protection Unit 15 Connecting the Protection Unit 16 Disconnecting the Protection Unit 16 How to Start Charging 17 Troubleshooting 17...

Page 13: ...nsion cord only connect the mains plug into a fixed mains socket To prevent fires from overheating do not use the product in old electrical wiring of unknown quality Do not operate a damaged product R...

Page 14: ...ns Ensure that the mains plug is disconnected prior to moving the product Do not damage the cables by bending it excessively or placing a heavy object on top The product shall be handled according to...

Page 15: ...ded Ready Flashing Continuous Charging Ground Fault Fault Ground Fault Warning Colour Status Indicators on the Protection Unit BLUE RED YELLOW GREEN IEC 62196 2 Type 2 Male 607 cm 157 cm 17cm Charging...

Page 16: ...3 Ensure that the lock snaps securely into place Disconnecting the Protection Unit 1 Press the lever to unlock the plug from the Protection Unit 2 Remove cable from the Protection Unit by pulling the...

Page 17: ...the mains plug from the mains socket Troubleshooting Follow the steps below if the product does not power up red light is glowing or the electric vehicle does not start charging 1 Remove the EV plug f...

Page 18: ...plug are disconnected 2 Place the Isolation Unit horizontally on a flat surface with natural drainage 3 Pour a steady stream of fresh water into the inlet vent until the water leaving from the outlet...

Page 19: ...3 6kW Legrand Green Up Max 14A Max 3 2kW Schuko CEE 7 7 Max 10A Max 2 3kW Grid Type IT TN TT Electrical Protection Fuses RCD with Redundancy General Voltage Rating 230VAC 10 Phases 1 Phase Frequency...

Page 20: ...Zaptec Charger AS Prof Olav Hanssensvei 7A 4021 Stavanger Norway ZAPTEC Charger MADE IN NORWAY ZAPTEC Charger AS 2017 All rights reserved ZM000390 2...

Reviews: