Water contains, a variable quantity of
limestone and mineral salts of which
quantities vary according to
geographical locations thus varying its
conductivity values.
Relevant variations of the conductivity
of the water compared to those
prefixed by the factory could slightly
influence the residual humidity of the
laundry at the end of the cycle.
Your dryer allows you to regulate the
sensitivity of the drying sensor based
on conductivity values of the water by
using the following procedure.
To access adjustment mode:
Turn the programme selector dial to
switch on the appliance. In selection
mode, press simultaneously the
buttons 3 and 6.
Press the buttons down until the pilot
lights above each ones begin to flash
and one of the pilot lights indicating the
drying phase lights FILTER,
WATERHOUDER, or CONDENSOR
remains lit.
Adjusting the level of conductivity:
Press the START/PAUZE (6) button
sequentially: the level of conductivity is
indicated by the phase pilot lights,
which light in various combinations as
follows:
1 2 3 4 5
6
27
Adjusting level of conductivity
Display Conductivity
degree
Approximative
value (µS/cm)
CCOO
Low
< 300
CCOO
Medium
300 - 600
CCOO
High
> 600
1 2 3 4 5
6
3