INSTALLATION
WARNING! Refer to Safety chapters.
POSITIONING
Install the appliance in a dry, well ventilated indoors
where the ambient temperature corresponds to the
climate class indicated on the rating plate of the
appliance.
Climate
class
Ambient temperature
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Some functional problems might occur
for some types of models when
operating outside of that range. The
correct operation can only be
guaranteed within the specified
temperature range. If you have any
doubts regarding where to install the
appliance, please turn to the vendor,
to our customer service or to the
nearest Authorised Service Centre.
LOCATION
Refer to the assembly instructions for
the installation.
To ensure best performance, install the appliance
well away from sources of heat such as radiators,
boilers, direct sunlight etc. Make sure that air can
circulate freely around the back of the cabinet.
ELECTRICAL CONNECTION
CAUTION! Any electrical work
required to install this appliance
should be carried out by a qualified
electrician or competent person.
WARNING! This appliance must be
earthed.
The manufacturer declines any liability
should these safety measures not be
observed.
The wires in the mains lead are coloured in
accordance with the following code:
A
B
C
D
E
• A - green and yellow: Earth
• C - brown: Live
• D - blue: Neutral
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
1. Connect the wire coloured green and yellow to
the terminal marked either with the letter “E“ or
by the earth symbol or coloured green and
yellow.
2. Connect the wire coloured blue to the terminal
either marked with the letter “N“ or coloured
black.
3. Connect the wire coloured brown to the
terminal either marked with the “L“ or coloured
red.
4. Check that no cut, or stray strands of wire is
present and the cord clamp (E) is secure over
the outer sheath.
Make sure the electricity supply voltage is the
same as that indicated on the appliance rating
plate.
5. Switch on the appliance.
The appliance is supplied with a 13 amp fuse (B).
In the event of having to change the fuse in the plug
supplied, a 13 amp ASTA approved (BS 1362)
fuse must be used.