mostatic control for some hours so that it
can reach the sufficient storing tempera-
ture as soon as possible.
Important!
Never use sharp metal tools to
scrape off frost from the evaporator as you
could damage it. Do not use a mechanical
device or any artificial means to speed up the
thawing process other than those
recommended by the manufacturer. A
temperature rise of the frozen food packs,
during defrosting, may shorten their safe
storage life.
Troubleshooting
Caution!
Before troubleshooting,
disconnect the power supply.
Only a qualified electrician or competent
person must do the troubleshooting that is not
in this manual.
Important!
There are some sounds during
normal use (compressor, refrigerant
circulation).
Problem
Possible cause
Solution
The appliance is noisy.
The appliance is not supported
properly.
Check if the appliance stands stable
(all the four feet should be on the
floor).
The compressor operates
continually.
The Temperature regulator may be
set incorrectly.
Set a warmer temperature.
The door is not closed correctly.
Refer to "Closing the door".
The door has been opened too fre-
quently.
Do not keep the door open longer
than necessary.
The product temperature is too
high.
Let the product temperature de-
crease to room temperature before
storage.
The room temperature is too high.
Decrease the room temperature.
Water flows on the rear
plate of the refrigerator.
During the automatic defrosting
process, frost defrosts on the rear
plate.
This is correct.
Water flows into the refrig-
erator.
The water outlet is clogged.
Clean the water outlet.
Products prevent that water flows
into the water collector.
Make sure that products do not
touch the rear plate.
Water flows on the ground.
The melting water outlet does not
flow in the evaporative tray above
the compressor.
Attach the melting water outlet to the
evaporative tray.
There is too much frost
and ice.
Products are not wrapped properly.
Wrap the products better.
The door is not closed correctly.
Refer to "Closing the door".
The Temperature regulator may be
set incorrectly.
Set a higher temperature.
The temperature in the ap-
pliance is too low.
The Temperature regulator may be
set incorrectly.
Set a higher temperature.
23
www.zanussi.com