Electrical connection
Prior to making the electrical connection, make sure that:
— the protection fuse and the domestic wiring
system are suitable to carry the total electric load of
the oven (see rating plate);
— your domestic wiring system has an
efficient earth connection in compliance with rules
and laws in force;
— the wall socket or the omnipole switch used
for the electrical connection can easily be reached
after the oven is built in.
This appliance is delivered without an electric supply
cable, therefore, you will have to fit to it a supply cable
with standard plug, suitable for the total electric load
shown on the rating plate. The plug is to be inserted into
a suitable wall socket. If you require a direct connection
to the electric network (mains), it will be necessary to fit
between the appliance and the mains an omnipole
switch, with a minimum gap between contacts of 3 mm,
suitable for the required load and in compliance with
rules in force. The green & yellow ground wire must
not be interrupted by the switch, and should be 2-3 cm
longer than the phase and neutral wires. The supply
cable must in all cases be laid out in such a way as to
ensure that it does not reach at any given point a
temperature 50°C higher than the ambient
temperature.
Suitable power supply cables are the following types,
considering the respective necessary section of cable:
H07 RN-F, H05 RN-F, H05 RR-F, H05 VV-F, H05
V2V2-F (T90), H05 BB-F.
Connecting the terminal board
The appliance incorporates an easily accessible
6-pole terminal board whose jumpers (bridges) are
already pre-set for operation on 400 V tri-phase with
neutral wire (Fig. 5). In case a different mains voltage is
present, the jumpers on the terminal board must be
rearranged as shown in the diagram (Fig. 6). The
ground cable must be connected to terminal
. After
connecting the supply cable to the terminal board,
secure it with a junction clamp.
230V 3~
1 2 3 4 5
L1 L2 L3 PE
230V 1~
1 2 3 4 5
L1 N PE
400V 2N~
1 2 3 4 5
L1 L2 N PE
400V 3N~
1 2 3 4 5
L1 L2 L3 N PE
FO 0330
Ø 4x2,5mm²
Ø 3x2,5mm²
Ø 4x2,5mm²
Ø 5x1,5mm²
Fig. 5
Fig. 6