BUILDING IN
3
6
589
595 +/-1
114
16
21
548
573
min. 550
20
6
600
558
min. 560
min. 550
20
589
595 +/-1
114
16
21
548
573
580
min. 560
558
9
SECURING THE APPLIANCE TO THE
CABINET
1. Open the appliance door.
2. Fasten the appliance to the cabinet.
3. Put the four distance holders (A) into the holes
in the frame and then tighten the four screws
(B) supplied with the appliance.
A
B
ELECTRICAL INSTALLATION
The manufacturer is not responsible if
you do not follow the safety
precautions from the Safety chapters.
This appliance is supplied without a main plug and
a main cable.
Applicable types of cables for Europe:
• Minimum size Cable / flex: 1,5 mm²
• Cable / flex type: H07 RN-F, H05 RN-F, H05
RRF, H05 VV-F, H05 V2V2-F (T90), H05 BB-F
Applicable types of cables for UK only
Connection via
Min. size cable / flex
Cable / flex type
Fuse
Oven Control Circuit
2,5 mm²
PVC / PVC twin and earth
15 A min.
20 A max.
ENERGY EFFICIENCY
PRODUCT FICHE AND INFORMATION ACCORDING TO EU 65-66/2014
Supplier's name
Zanussi
Model identification
ZOA35675WK
ZOA35675XK
ZOA35676WK
ZOA35676XK
21