17
Burner
Nominal Power LPG (Butane "A")
Diameter
Feeding
Tap. By-Pass
Pressure
kW
kCal/h
Nozzle
g/h
mbar (*)
Auxiliary
0,95
814
50
75
28
Semi-rapid
1,60
1368
65
126
35
30
Rapid
2,45
2095
80
193
45
Double crown
3
2562
90
236
56
100
650
100
100
500
650
500
Location
In order to function normally it is imperative that this unit
is installed in a well ventilated kitchen (regarding the
installation follow the existing regulations). The appliance
is of freestanding type and must be installed according
to the existing regulations.
For the insertion possibilities, please refer to fig. 12.
The minimum distance combustible material can be fitted
directly above the cooker is 650 mm.
Since the appliance is supplied with
adjustable feet, it should be located as shown
in the diagrams, according to the height
adjustment.
Dimensions of the appliance
Height
830/910 mm
Depth
600 mm
Width
700 mm
Oven Capacity
53 dm
3
Appliance category:
I3
Appliance gas supply:
LPG 30mbar
Technical Data
Electric Oven ratings
Top/Bottom Heating Element
1800 W
Grill Element
1750 W
Convection Fan
30
W
Oven light
15 W
Total rating
18
5
0 W
Supply voltage (50 Hz)
230 V
Characteristics of Burners, Nozzles and Taps
Instructions for the installer
Fig. 12
(*) 1 mbar = 10 mm. water coloumn.