25
1
Safety Instructions for
the Installer
•
A device must be provided in the electrical installa-
tion which allows the appliance to be disconnected
from the mains at all poles with a contact opening
width of at least 3 mm.
Suitable isolation devices include line protecting
cut-outs, fuses (screw type fuses are to be re-
moved from the holder), earth leakage trips and
contactors.
•
In respect of fire protection, this appliance corre-
sponds to EN 60 335-2-6. This type of appliance
may be installed with a high cupboard or wall on
one side.
•
Drawers may not be fitted underneath the hob.
•
The installation must guarantee shock protection.
•
The kitchen unit in which the appliance is fitted
must satisfy the stability requirements of
DIN 68930.
•
For protection against moisture, all cut surfaces
are to be sealed with a suitable sealant.
•
On tiled work surfaces, the joints in the area where
the hob sits must be completely filled with grout.
•
On natural, artificial stone, or ceramic tops, the
snap action springs must be bonded in place with
a suitable artificial resin or mixed adhesive.
•
Ensure that the seal is correctly seated against the
work surface without any gaps. Additional silicon
sealant must not be applied; this would make re-
moval more difficult when servicing.
•
The hob must be pressed out from below when re-
moved.
Summary of Contents for ZKT663
Page 28: ...82 Assembly Montage ...
Page 29: ...83 ...