13
Venting
The hood is more effective when used in the
extraction setting (ducted to the outside).
Venting kits may be purchased through your
retailer or DIY store, and must be ducted to
an outside vent of 100mm (4”) minimum.
The ducting used must be manufactured from
fire retardant material which should conform to
the relevant British Standard or DIN4102-B1.
When the hood is ducted externally the
charcoal filter must be removed and the
slider control must be in the ducting position.
To Fit the Ducting
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø120 mm,
the choice of which is left to the installer.
1
Fix the pipe in position using sufficient pipe clamps
(not supplied).
2
Remove any activated charcoal filters.
Recirculation
The charcoal filter must be
fitted for recirculation and the slider control
must be in the recirculation position.
Fitting the Cooker Hood to the Wall
1
Make sure that the hood body has been completely
fixed.
2
Make sure that hood is equipped with charcoal
filters.
�����
�
Ø 100