IMPORTANT SAFETY INFORMATION

These warnings are provided in the interests of your safety. Ensure that you understand them all before
installing or using this appliance. Your safety is of paramount importance. If you are unsure about any of
the meanings of these warnings contact the Customer Care Department.

Installation

Any  installation  work  must  be  undertaken  by  a

qualified electrician or a competent person.

This hood must be installed in accordance with the

installation instructions and all measurements must
be adhered to.

If the cooker hood is installed for use above a gas

appliance then the provision for ventilation must be
in accordance with the Gas Safety Codes of Practice
BS.6172, BS.5440 and BS.6891 (Natural Gas) and
BS.5482 (LP Gas) 1994, the Gas Safety (Installation
& Use) Regulations, the Building Regulations issued
by the Department of the Environment, the Building
standards  (Scotland)  (Consolidated)  Regulations
issued by the Scottish Development Department.

The fan motor of this cooker hood incorporates a cut-

out device which will operate if the cooker hood is
installed  below  the  minimum  height  recommended
under  section  ‘Clearance  Height’,  or  if  the  motor
becomes  overheated.  If  the  cut-out  device  is
activated,  switch  off  the  fan  motor  and  allow  the
cooker  hood  to  cool.  The  cut-out  device  will  reset
itself when the fan motor has cooled significantly.

It is dangerous to alter the specifications or modify

this product in any way.

When installed between adjoining wall cabinets the

wall cabinets must not overhang the hob.

If the room where the hood is to be used contains a

fuel burning appliance such as a central heating boiler
then its flue must be of the room sealed or balanced
flue type.

If other types of flue or appliances are fitted ensure

that there is an adequate supply of air to the room.

The  ducting  system  for  this  appliance  must  not  be

connected to any existing ventilation system which
is being used for any other purpose.

Do not install above a cooker with a high level grill.

Child Safety

This appliance is designed to be operated by adults.
Children  should  not  be  allowed  to  tamper  with  the
controls or play with the appliance.

During Use

This product is for domestic use only.

Never  leave  frying  pans  unattended  during  use  as
over-heated fats and oils might catch fire.

Never do flambé cooking under this cooker hood.

Do not leave naked flames under the hood.

Maintenance and Service

This appliance can be a hazard if the synthetic paper
and  charcoal  filters  are  not  replaced  as
recommended.

Under no circumstances should you attempt to repair
the  appliance  yourself.  Repairs  carried  out  by
inexperienced  persons  may  cause  injury  or  more
serious  malfunction.  Refer  to  your  local  Zanussi
Service Force Centre. Always insist on genuine spare
parts.

Summary of Contents for ZHC 925

Page 1: ...COOKER HOOD ZHC 925 INSTRUCTION BOOKLET ...

Page 2: ...plete and return the guarantee card supplied with the appliance Guide to use the instruction book The following Symbols will be found in the text to guide you through the instruction book Safety instructions Step by step instructions For the User Important Safety Information Your Appliance Operating Instructions Cooker Hood Controls To Operate Recirculation Extraction Maintenance and Cleaning Exte...

Page 3: ...he cut out device will reset itself when the fan motor has cooled significantly It is dangerous to alter the specifications or modify this product in any way When installed between adjoining wall cabinets the wall cabinets must not overhang the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or...

Page 4: ...functions are controlled by five push button switches located centrally in the control fascia T1 Turns the worktop lighting On and Off T2 Turns the fan motor On and Off T3 Decreases the fan speed T4 Increases the fan speed T5 Intensive fan speed with timed programme Select when cooking foods with strong odours or when frying To cancel depress the button again F C T1 T2 T3 T4 T5 ...

Page 5: ...k Extraction In the extraction mode the contaminated air enters the cooker hood passing through the grease filters and is passed out through the ducting into the atmosphere To obtain the best performance when cooking it is advisable to switch the cooker hood on for a few minutes before you start cooking and leave it running for about 15 minutes after finishing When used in the ducting mode the cha...

Page 6: ...2 starts to flash or at least once every month using a normal household detergent their compact dimension also enables them to be washed in a dishwasher Allow to dry completely before replacing Replacing Remove the filters one at a time press against the metal catch to release the spring catch as illustrated in Fig 1 When replacing ensure that the handles face outwards Enabling the alarm signal Th...

Page 7: ... To replace the charcoal filter place the filter over the inlet grille and while holding the filter with one hand insert the screw and tighten by hand as illustrated in Fig 3 This appliance can be a possible fire hazard if the grease and charcoal filters are not cleaned and replaced as recommended Changing the Light Bulb Unsrew the two screws from the frame around the lamp lens as illustrated in F...

Page 8: ...he entry of fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out device has been tripped Turn off the hob and then wait for the device to reset In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is n...

Page 9: ... incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are the subject of rental agreements Products of Zanussi manufacture which are not marked by Zanussi This guarantee is in addition to your statutory and legal rights ZANUSSI EUROPEAN GUARANTEE If you should...

Page 10: ...electrical installation must comply with the latest I E E Regulations and local Electricity Board regulations For your own safety this should be undertaken by a qualified electrician e g your local Electricity Board or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting NICEIC Electrical Connection Before connecting to the mains supply ensure ...

Page 11: ...sed in the extraction ducted to the outside or recirculation mode The installation work must be undertaken by a qualified and competent person The manufacturer disclaims any responsibility for damage due to incorrect installation of the cooker hood or if the hood is not installed in compliance with relevant regulations controlling this type of installation Unpacking The hood is supplied with the f...

Page 12: ...ease refer to the cooker manufacturer s installation instructions A minimum clearance height of 650 mm 251 2 ins is required when installed above a built in electric hob or 700 mm 271 2 ins when installed above a built in gas hob A minimum clearance height of 685 mm 27 ins is required when installing above a slot in electric cooker or 787 mm 301 2 ins when installed above a slot in cooker When ins...

Page 13: ...ght of the upper chimney Place the bottom edge of the bracket against the line aligning the centre of the bracket with the vertical line If the alignment is correct mark the centres for the keyhole fixing screws not supplied as illustrated in Fig 7 a Drill the holes for the fixing screws and fix the wall brackets Ensure that the distance between the lowest point of the hood and the cooking applian...

Page 14: ...sed in the extraction mode ducted to the outside Venting kits may be purchased through your retailer or DIY store and must be ducted to an outside vent of 125mm 5 The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN 4102 B1 When the cooker hood is ducted to the outside the charcoal filter must be removed Recirculation The cooker hood...

Page 15: ...lled to be reduced 1 metre for each 90o bend installed in the ducting run If the distance is greater than 3 metres the efficency of the hood could be impaired The diameter of the spigot on top of the hood is 150mm 6ins When 125mm ducting is to be used it will be necessary to install the ducting adapter A 150mm 6ins to 120mm 5ins and the ducting collar B 120mm to 125mm as illustrated in Fig 11 If t...

Page 16: ...himney slightly to allow it to be fitted over the upper chimney S and the canopy C as illustrated in Fig 8 Secure the bottom of the chimney to the canopy using the self tapping screws provided as illustrated in Fig 12 After the chimney has been secured into position insert the two plastic recirculation grilles in to the apertures on each side of the chimney The grilles are marked with two arrows a...

Page 17: ...17 ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...4329620 03 010910 Electrolux Household Appliances Limited 2001 ...

Reviews: