background image

18

Summary of Contents for ZHC 613

Page 1: ...COOKER HOOD ZHC 613 ZHC 913 INSTRUCTION BOOKLET ...

Page 2: ...formation Your Appliance Operating Instructions Cooker Hood Controls To Operate Recirculation Extraction Maintenance and Cleaning External Cleaning Metal Grease Filters Charcoal Filters To Remove Replace Charcoal Filter Changing the Light Bulb Something Not Working Service and Spare Parts Guarantee Conditions For the Installer Technical Information Electrical Connections Electrical Requirements El...

Page 3: ...he cut out device will reset itself when the fan motor has cooled significantly It is dangerous to alter the specifications or modify this product in any way When installed between adjoining wall cabinets the wall cabinets must not overhang the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or...

Page 4: ...d Controls The cooker hood functions are controlled by three switches located to the right on the underside of the hood immediately in front of the metal grease filters Worktop Lighting The switch L marked with the lamp symbol operates the worktop lighting L 0 OFF 1 ON Fan Control The switch M marked with the fan symbol and the switch V marked 1 2 3 operates the fan M 0 OFF 1 ON V 1 Low 2 Normal 3...

Page 5: ...e grease filters and is passed out through the ducting into the atmosphere To obtain the best performance when cooking it is advisable to switch the cooker hood on for a few minutes before you start cooking and leave it running for about 15 minutes after finishing When used in the ducting mode the charcoal filters are not required Never do flambé cooking under this cooker hood Never leave frying p...

Page 6: ...e excessive amounts of water when cleaning particularly around the control panel Metal Grease Filters The grease filters absorb grease and dust during cooking to help keep the cooker hood clean inside and should be cleaned approximately once every month or more often if the hood is used for more than 3 hours a day Remove the metal grease filters one at a time by Releasing the catches on the filter...

Page 7: ...into position This appliance can be a possible fire hazard if the grease and charcoal filters are not cleaned and replaced as recommended Changing the Light Bulb 1 First remove the metal grease filters 2 The light bulbs can be reached from inside the canopy 3 Rotate the light bulb anti clockwise to unscrew 4 To replace the light bulb insert a replacement into the holder then rotate the bulb clockw...

Page 8: ...e entry of fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out device has been tripped Tum off the hob and then wait for the device to reset In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not...

Page 9: ...tic Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are the subject of rental agreements Products of Zanussi manufacture which are not marked by Zanussi This guarantee is in addition to your statutory and legal rights ZANUSSI EUROPEAN GUARANTEE If y...

Page 10: ...e must be earthed Electrical Requirements Any permanent electrical installation must comply with the latest I E E Regulations and local Electricity Board regulations For your own safety this should be undertaken by a qualified electrician e g your local Electricity Board or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting NICEIC Electrical ...

Page 11: ... over a cooking area and can be used in the extraction ducted to the outside or recirculation mode The installation work must be undertaken by a qualified and competent person The manufacturer disclaims any responsibility for damage due to incorrect installation of the cooker hood or if the hood is not installed in compliance with relevant regulations controlling this type of installation Unpackin...

Page 12: ...joining wall cabinets the wall cabinets must not overhang the hob and the distance between the underside of the cabinet and the worktop must be 450mm If the height of the wall cabinet is less than 450mm a gap of 50mm must be maintained either side of the hob This cooker hood must not be installed above a cooking appliance with a high level grill Fitting the Wall Brackets 1 Draw a vertical line on ...

Page 13: ... the bottom Note If the hood is to be installed onto a hollow construction or plaster or partition board wall then special fixing screws will be required not supplied Fitting the Canopy Hood 1 Rotate the adjusting screws R on the canopy C to about halfway 2 Hook the canopy C onto the wall fixing bracket 1 and push down until the canopy adjusting screws R rest on the lugs 3 To align or adjust the h...

Page 14: ...ds of more than 90º will reduce the efficency of the hood and reduce airflow The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN 4102 B1 When the cooker hood is ducted to the outside the charcoal filters must be removed Recirculation If you are using the hood for recirculation ensure the charcoal filters are in position following th...

Page 15: ...panding the chimney slightly to allow it to be fitted over the brackets 1 and the upper chimney section and bracket 3 3 Ensure the bottom edge of the chimney stack is fitted correctly into the recess around the top of the canopy and secured using the two self tapping screws as illustrated in the close up above Note The upper S and lower I chimney stack sections are fixed to the middle wall bracket...

Page 16: ...16 ...

Page 17: ...17 ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ... Electrolux Household Appliances Limited 2000 4329515 04 010905 ...

Reviews: