TECHNICAL DATA
HOB DIMENSIONS
Width
740 mm
Depth
510 mm
BYPASS DIAMETERS
BURNER
Ø BYPASS 1/100 mm
Multi Crown
57
Semi-rapid
35
Auxiliary
28
OTHER TECHNICAL DATA
TOTAL POW-
ER:
Gas original:
G20 (2H) 20 mbar
10,45 kW
Gas replace-
ment:
G30 (3+) 28-30 mbar
745 g/h
G31 (3+) 37 mbar
732 g/h
Electric supply:
220-240 V ~ 50-60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse
Appliance cate-
gory:
II2H3+
Gas connec-
tion:
R 1/2"
Appliance
class:
3
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW MINIMUM POWER kW
INJECTOR MARK
Multi Crown
3,9
1,4
146
Semi-rapid
1,85
0,6
92
Auxiliary
1,0
0,33
70
WARNING! This appliance does not
function with the existing gas settings
if installed in Malta. Therefore, before
connecting the appliance it is essential
to change the nozzles according to the
type of gas used according to the
table below.
15