background image

8

FITTING THE GAS HOB

WITHOUT A COOKER HOOD ABOVE

FITTING THE GAS HOB

WITH A COOKER HOOD ABOVE

700 mm

400 mm

400 mm

100 mm

55 mm

50 mm

50 mm

600 mm

700 mm

400 mm

400 mm

100 mm

55 mm

600 mm

50 mm

50 mm

FO 2369*

FO 2231*

Important safety requirements

This hob must be installed in accordance with the Gas
Safety (Installation and Use) Regulations (Current
Edition) and the IEE Wiring Regulations (Current
Edition). Detailed recommendations are contained in the
following British Standards Codes Of Practice: B.S.
6172/ B.S. 5440, Part 2 and B.S. 6891 Current Editions.
The hob should not be installed in a bed sitting room
with a volume of less than 20 m

3

. If it is installed in a

room of volume less than 5 m

3

 an air vent of effective

area of 110 cm

2

 is required. If it is installed in a room of

volume between 5 m

3

 and 10 m

3

 an air vent of effective

area of 50 cm

2

 is required, while if the volume exceeds

11 m

3

 no air vent is required. However, if the room has a

door which opens directly to the outside no air vent is
required even if the volume is between 5 m

and 11 m

3

.

If there are other fuel burning appliances in the same
room, B.S. 5440 Part 2 Current Edition, should be
consulted to determine the requisite air vent
requirements.

Location

The hob may be located in a kitchen, a kitchen/diner or
bed sitting room, but not in a bathroom or shower room.
Before making the cut out in the worktop ensure that
the edges of the hob that are to be near either a side or
rear wall have a minimum distance of 55 mm. between
the edge of the hob and the wall.
The minimum distance combustible material can be
fitted above the hob is 400 mm. If it is fitted below 400
mm. a space of 50 mm. must be allowed from the edges
of the hob. The minimum distance combustible material
can be fitted directly above the hob is 700 mm. A
minimum distance of 100 mm. must be left between the
side edges of the hob and any adjacent cabinets or walls.

Summary of Contents for ZGM 782

Page 1: ...GAS HOB ZGM 782 INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance GB ...

Page 2: ... person to ensure that they can use the appliance safely During Use z This hob is intended for domestic cooking only It is not designed for commercial or industrial purposes z When in use a gas cooking appliance will produce heat and moisture in the room in which it has been installed Ensure there is a continuous air supply keeping air vents in good condition or installing a cooker hood with a ven...

Page 3: ...on Hints and Tips Environmental Information Environmental Information z After installation please dispose of the packaging with due regard to safety and the environment z When disposing of an old appliance make it unusable by cutting off the cable z The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the...

Page 4: ...4 1 Auxiliary Burner 2 Semi rapid Burners 3 Rapid Burner 4 Ultra rapid Triple crown Burner 5 Control knobs Description of the Hob 1 2 2 3 4 5 ...

Page 5: ... maintenance or cleaning can be carried out you must DISCONNECT the hob from the electricity supply The hob is best cleaned whilst it is still warm as spillage can be removed more easily than if it is left to cool The Hob Top Regularly wipe over the hob top using a soft cloth well wrung out in warm water to which a little washing up liquid has been added Avoid the use of the following household de...

Page 6: ...cap and crown have been replaced correctly e g after cleaning If after all these checks your hob still does not operate correctly contact your local Zanussi Service Force Centre Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the faul...

Page 7: ... with a 3 amp cartridge fuse Ignition HT Spark Spark Generator Ispra Control s BF 80066 220 240V 0 6 VA T 120 Spark Gap Fixed Rear Left Burner rapid Heat Input 2 8 kW Natural Gas 10239 BTU HR 2 8 kW L P G 9556 BTU HR Front Left Burner auxiliary Heat Input 1 0 kW 3413 BTU HR Rear Right Burner semi rapid Heat Input 2 0 kW 6824 BTU HR Front Right Burner semi rapid Heat Input 2 0 kW 6824 BTU HR Centra...

Page 8: ... is required while if the volume exceeds 11 m3 no air vent is required However if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3 If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements Location The hob may be located ...

Page 9: ... the G 1 2 threaded elbow adjustment is fixed so that the washer is fitted between the components as shown in the diagram Screw the parts together without using excessive force Gas Connection Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The connection should be suitable for connecting to R 1 2 1 2 BSP male thread When the final connection has been...

Page 10: ... hob a should be easily removable to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections ON OFF SWITCH FLEX OUTLET ON OFF SWITCH FLEX OUTLET FO 2563 FO 2564 FO 2044 1 2 3 Fitting the Hob into the worktop Carry out the building in of the hob as follows put the seals supplied with the hob on the edges of the cut out place them exactly o...

Page 11: ...r E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black Connect the brown live wire to the terminal in the plug which is marked with the letter L or coloured red Upon completion there must be no cut or stray strands of wire present and the cord clamp must be secure over the outer sheath A cut...

Page 12: ...has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of localburning arcingbutnofaultcouldbefoundunder test However a detailed visual inspection should reveal evidence of burning around the fault START Isolate appliance and carry out A Earth Con...

Page 13: ...ight burner manually Check gas supply at burner Check continuity from N on the mains connector block and N on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit L Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insul...

Page 14: ...and ignite another burner The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar Turn off the burner supplies Minimum adjustment screw Conversion from Natural Gas to LPG It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted The gas rate is adjust...

Page 15: ...hin a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacturer that are not marketed by Electrolux Service and Spare Parts In the event of your appliance requiring service or if you wish to purchase spare parts please contact your local Service Force Centre by telephoning 0870 5 929 929 Your telephone call will be automatically routed to the Serv...

Page 16: ...of the appliance The appliance guarantee is for the same period and to the same extent for labour and parts as exists in your new country of residence for this particular model or range of appliances The appliance guarantee is personal to the original purchaser of the appliance and cannot be transferred to another user The appliance is installed and used in accordance with instructions issued by E...

Page 17: ...17 ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...35679 0202 11 06 Grafiche MDM Forlì www zanussi electrolux co uk ...