WARNING! Make sure the flame does
not go out when you quickly turn the
knob from the maximum position to the
minimum position.
ELECTRICAL CONNECTION
• Make sure that the rated voltage and type of
power on the rating plate agree with the voltage
and the power of the local power supply.
• This appliance is supplied with a mains cable. It
has to be supplied with a correct plug which
can hold the load that the rating plate rates.
Make sure that you install the plug in a correct
socket.
• Always use a correctly installed shockproof
socket.
• Make sure that there is an access to the mains
plug after the installation.
• Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
• There is a risk of fire when the appliance is in
connection with an extension cable, an adapter
or a multiple connection. Make sure that the
ground connection agrees with the standards
and regulations.
• Do not let the power cable to heat up to a
temperature higher than 90° C.
CONNECTION CABLE
To replace the connection cable use only the
special cable or its equivalent. The cable type is:
H03V2V2-F T90.
Make sure that the cable section is applicable to
the voltage and the working temperature. The
yellow / green earth wire must be approximately 2
cm longer than the brown (or black) phase wire.
L
N
1. Connect the green and yellow (earth) wire to
the terminal which is marked with the letter 'E',
or the earth symbol , or coloured green and
yellow.
2. Connect the blue (neutral) wire to the terminal
which is marked with the letter 'N' or coloured
blue.
3. Connect the brown (live) wire to the terminal
which is marked with the letter 'L'. It must
always be connected to the network phase.
ASSEMBLY
1.
2.
3.
min. 55 mm
min. 650 mm
550 mm
2
0
+
min. 100 mm
30 mm
470 mm
2
0
+
4.
8