background image

A) supplied seal

B) supplied brackets

10.

11.

CAUTION!

Install the appliance only on a

worktop with flat surface.

Possibilities for insertion

The panel installed below the hob must be easy

to remove and let an easy access in case a

technical assistance intervention is necessary.

Kitchen unit with door or drawer

min 6 mm

min 20 mm

(max 150 mm)

min 30 mm

60 mm

B

A

A. Removable panel

B. Space for connections

Kitchen unit with oven

The electrical connection of the hob and the

oven must be installed separately for safety

reasons and to let easy remove oven from the

unit.

Technical data

Hob dimensions

Width

744 mm

Depth

510 mm

Bypass diameters

BURNER

Ø BYPASS 1/100 mm

Triple Crown

56

Rapid

42

Semi-rapid

32

Auxiliary

28

www.zanussi.com

15

Summary of Contents for ZGG75XA

Page 1: ...EN ZGG76524 ZGG75524 ZGG75XA User Manual Hob GB IE ...

Page 2: ...reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved Do not let children play with the appliance Keep all packaging away from children and dispose of it appropriately Keep children and pets away from the appliance when it operates o...

Page 3: ...amaged it must be replaced by the manufacturer an authorized Service or similarly qualified persons in order to avoid a hazard Where the appliance is directly connected to the power supply an all pole isolating switch with a contact gap is required Complete disconnection in compliance with the conditions specified in overvoltage category III must be guaranteed The earth cable is excluded from this...

Page 4: ...plate agrees with the power supply If not contact an electrician Make sure the appliance is installed correctly Loose and incorrect electricity mains cable or plug if applicable can make the terminal become too hot Use the correct electricity mains cable Do not let the electricity mains cable tangle Make sure that a shock protection is installed Use the strain relief clamp on the cable Make sure t...

Page 5: ... the cooking zones with empty cookware or without cookware Do not put aluminium foil on the appliance Use only stable cookware with the correct shape and diameter larger than the dimensions of the burners Make sure cookware is centrally positioned on the burners Make sure the flame does not go out when you quickly turn the knob from the maximum to the minimum position Use only the accessories supp...

Page 6: ...at the external gas pipes Service To repair the appliance contact an Authorised Service Centre Use original spare parts only Product description Cooking surface layout 3 4 5 2 1 1 Semi rapid burner 2 Triple Crown burner 3 Rapid burner 4 Auxiliary burner 5 Control knobs Control knob Symbol Description no gas supply off position Symbol Description ignition position maximum gas supply minimum gas sup...

Page 7: ...ARNING Do not keep the control knob pushed for more than 15 seconds If the burner does not light after 15 seconds release the control knob turn it into off position and try to light the burner again after minimum 1 minute CAUTION In the absence of electricity you can ignite the burner without electrical device in this case approach the burner with a flame turn the control knob counter clockwise to...

Page 8: ...kware Use cookware with diameters applicable to the size of burners Burner Diameter of cookware mm Triple Crown 180 260 Rapid 180 260 Semi rapid front 120 180 Semi rapid rear 120 220 Auxiliary 80 180 Care and cleaning WARNING Refer to Safety chapters General information Clean the hob after each use Always use cookware with clean bottom Scratches or dark stains on the surface have no effect on how ...

Page 9: ...brasive detergent After cleaning wipe the hob dry with a soft cloth To clean the enamelled parts cap and crown wash them with warm soapy water and dry them carefully before you put them back on Cleaning the spark plug This feature is obtained through a ceramic ignition candle with a metal electrode Keep these components well clean to prevent difficult lighting and check that the burner crown holes...

Page 10: ...icing by a service technician or dealer will not be free of charge also during the warranty period The instructions about the Service Centre and conditions of guarantee are in the guarantee booklet Labels supplied with the accessories bag Stick the adhesive labels as indicated below MOD PROD NO SER NO DATA MOD PROD NO SER NO DATA MOD PROD NO SER NO 03 IT MADE IN ITALY TYPE IP20 0049 A B C A Stick ...

Page 11: ...m The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400 mm If it is fitted below 400 mm a space of 50 mm must be allowed from the edges of the hob For appliances installed in the Republic of Ireland please refer to NSAI Domestic Gas Installation I S 813 Current Edition Section 7 Permitted Locations of Appliance Gas Connection WARNING Any gas...

Page 12: ...ss screw in from liquid gas to natural gas G20 20 mbar undo the bypass screw approximately 1 4 of a turn 1 2 of a turn for Triple Crown burner WARNING Make sure the flame does not go out when you quickly turn the knob from the maximum position to the minimum position Electrical connection Do not pull the mains cable to disconnect the appliance Always pull the mains plug if applicable The appliance...

Page 13: ...ent of the connection cable The replacement of electric cable must be carried out exclusively by the service force centre or by personnel with similar competencies in accordance with the current regulations To replace the connection cable use only H03V2V2 F T90 or equivalent type Make sure that the cable section is applicable to the voltage load and the working temperature The yellow green earth w...

Page 14: ...n 150 mm 30 mm 480 mm min 600 mm 4 50 mm 400 mm If a furniture unit is installed at a distance of 400 mm above the hob there must be a minimum safety distance of 50 mm to the left or right from the edge of the hob 5 6 7 8 9 A B 14 www zanussi com ...

Page 15: ...ecessary Kitchen unit with door or drawer min 6 mm min 20 mm max 150 mm min 30 mm 60 mm B A A Removable panel B Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit Technical data Hob dimensions Width 744 mm Depth 510 mm Bypass diameters BURNER Ø BYPASS 1 100 mm Tripl...

Page 16: ...ER kW MINIMUM POWER kW INJECTOR MARK Triple Crown 4 0 1 4 146 Rapid 3 0 0 75 119 Semi rapid 2 0 0 45 96 Auxiliary 1 0 0 33 70 Gas burners for LPG G30 G31 28 30 37 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK NOMINAL GAS FLOW g h G30 28 30 mbar G31 37 mbar Triple Crown 4 0 1 4 98 291 286 Rapid 2 8 0 75 86 204 200 Semi rapid 2 0 0 45 71 145 143 Auxiliary 1 0 0 33 50 73 71 Energy effici...

Page 17: ... General Energy saving Before use make sure that the burners and pan supports are assembled correctly Use cookware with diameters applicable to the size of burners Center the pot on the burner When you heat up water use only the amount you need If it is possible always put the lids on the cookware When the liquid starts to boil turn down the flame to barely simmer the liquid If it is possible use ...

Page 18: ...18 www zanussi com ...

Page 19: ...www zanussi com 19 ...

Page 20: ...www zanussi com shop 867329029 D 012017 ...

Reviews: