Testing in accordance with EN 60704 must be carried out with appliance fully loaded and using the test programme (see "Washing
programmes" chart).
Test in accordance with EN 50242 must be carried out when the salt container and rinse aid dispenser have been filled with salt and
rinse aid respectively and using the test programme (see "Washing programmes" chart).
Hints for test centres
17
Load:
9 standard place settings
Rinse aid setting:
position 4 (Type III)
Detergent dosage :
5 g + 20 g (Type B)
Cup racks: position A
Arrangement lower basket
Arrangement cutlery basket
Arrangement upper basket
without smaller bowl
and salad-bowl
Arrangement upper basket
with smaller bowl
and salad-bowl