A
Minimum distances
Dimension
mm
A
685
Levelling of the appliance
Use small feet on the bottom of appliance to set
the appliance top surface level with other
surfaces.
Electrical installation
WARNING!
The manufacturer is not responsible
if you do not follow the safety
precautions from Safety chapters.
This appliance is supplied without a main plug
or a main cable.
Applicable types of cables for different phases:
Phase
Min. size cable
1
3x10.0 mm²
3 with neutral
5x1.5 mm²
WARNING!
The power cable must not touch the
part of the appliance shaded in the
illustration.
Covering terminal board
• The recommended cross-section area is six
square millimetres (6 mm²).
• When you refit the mains terminal cover,
make sure that the lower tabs are located
inside the bottom edge of the aperture,
before you fix the two screws into the top
edge of the mains terminal cover.
• Make sure that the cover is securely
fastened.
To open the cover of terminal board
obey the procedure in opposite
sequence.
Terminal board
Do not remove blanking plates.
Make sure that the links are fitted as shown.
www.zanussi.com