5. Replace the rating plate (it is near the gas
supply pipe) with the one for the new type of
gas supply.
You can find this plate in the bag
supplied with the appliance.
If the supply gas pressure is not constant or it is
different from the necessary pressure, install an
applicable pressure adjuster on the gas supply
pipe.
ADJUSTING THE MINIMUM GAS LEVEL ON
THE HOB BURNER
1. Disconnect the appliance from the electricity.
2. Remove the knob for the hob. If there is no
access to the bypass screw dismount the
control panel before adjustment start.
3. With a thin and flat screwdriver adjust the
bypass screw A.
The model determines the position of the
bypass screw A.
A
A
Changing from natural gas to liquid gas
1. Fully tighten the bypass screw.
2. Put the knob back.
Changing from liquid gas to natural gas
1. Unscrew approximately one turn the bypass
screw position A.
2. Put the knob for the hob back.
3. Connect the appliance to the electricity.
WARNING! Put the mains plug
into the mains socket only if all
parts are back into their initial
position. There is a risk of injury.
4. Light the burner.
Refer to "Hob - Daily use" chapter.
5. Turn the knob for the hob to the minimum
position.
6. Remove the knob for the hob again.
7. Screw on slowly the bypass screw till the flame
becomes minimum and stable.
8. Put the knob for the hob back on.
OVEN INJECTOR REPLACEMENT
1. Remove the bottom plate of the oven cavity to
get access to the oven burner .
2. Carefully remove from the burner the
thermocouple A. Next remove the spark plug B.
A
B
3. Unscrew the screw and slowly pull out the
burner.
22