operating it. This adjustment
can be made by turning
the levelling feet clockwise
or anti-clockwise, if
required. It is possible
to raise the product up to
maximum of 35 mm
via the levelling feet. If it
becomes necessary
to move the appliance after the
levelling feet
have been adjusted, it is advisable to lift
and
not drag. The levelling feet can be adjusted by
hand or by using a metal coin of the correct size.
Connecting to the electricity
supply
This appliance must be earthed. Do not earth
this
appliance to gas supply piping. Connect to
230 -
240V AC supply only.
•
Connection to the electricity supply must be
carried
out by a qualified electrician/competent
person.
•
The electrical connection should be made
using a
double pole isolating switch (cooker
socket) with at
least 3mm contact separation
in all poles.
The
cable must have conductors of sufficiently high
cross-sectional area to prevent overheating and
deterioration.
• We recommend you use a new length of 6mm² twin
core earthed cable to ensure your safety.
• The cable should be routed away from potentially
hot areas.
Connection diagrams as given below:
!
WARNING!
N - Neutral
PE - Earth
L - Live
L
N
PE
This appliance must be earthed.
For this connection, ‹Twin and Earth 6242Y›
type cable should be used.
22
This appliance complies with: European Council
Directive 73/23/EEC, EMC Directive 89/336/
EEC, CE Marking Directive 93/68/EEC, Energy
Label Directive 2002/40/EC.
Technical Data
CERAMIC SOLID
Overall height of appliance to top of
hob
Maximum width of appliance
Maximum depth of appliance
Weight of the appliance
Technical Specifications for Top and Main Oven
Top Oven of 50x60 cooker Rating
Top Heating Element
Bottom Heating Element
Grill Heating Element
Main Oven of 50x60 cooker Rating
Ring Heating Element
895 mm
898 mm
495 mm
495 mm
656 mm
656 mm
45,1kg
43,9kg
500 W
600 W
1400 W
2000 W