24
Electrical Connection
The oven is designed to be connected to 230 -240 V (50
Hz) electricity supply.
The oven has an easily accessible terminal block which
is marked as follows.
Letter L
Live terminal
Letter N
Neutral terminal
Earth
The cable used (of the types: H05 V2V2-F T90, H05 BB-
F T90) must have a min. cross section of 1.5 mm
2
.
In order to connect it to the oven it is necessary to
remove the hatch at the back of the oven to reach the
terminal block.
For direct connection to the mains supply a two pole
switch with a minimum rating of 13 A and a minimum
distance of 3 mm between its contacts must be fitted
between the supply and appliance.
This switch must not break the yellow/green earth cable
at any point.
The appliance must be earthed
Technical Data
Dimensions of recess
Height
580 mm.
Width
560-570 mm.
Depth
550 mm.
Dimensions of the oven cavity
Height
325 mm.
Width
420 mm.
Depth
390 mm.
Oven capacity
53 litres
Heating elements rating
Top+Bottom heating elements
1880 W
Top element
835 W
Bottom element
1045 W
Convection element
2090 W
Grill element
1830 W
Double Grill element
2660 W
Pizza Oven Function
3135 W
Convection Fan
30 W
Oven Light
15 W
Cooling Fan
20 W
Total Rating
3.2 kW
Supply voltage (50 Hz)
230-240 V
This oven must be installed according to
standards and regulation currently in force.
The oven must be installed according to the
instructions supplied.
Installation
Important
After installation and connecting, the cable must be
placed so that is cannot at any point reach a temperature
more than 50°C above the ambient temperature.
Before the appliance is connected check that:
- the main fuse and the domestic installation can
support the load;
- the power supply is properly earthed;
- the double pole switch used to connect the appliance
to the supply is easily accessible after installation.
Terminal block
The oven has an easily accessible terminal block (Fig. 1),
which is meant to work with an electric single-phase rate
of 230-240 V.
The manufacturer disclaims any
responsability should all the safety
measures not be carried out.
Fig. 1
FO 2159
Summary of Contents for ZBM170
Page 27: ...27 ...