15
This might cause heat build-up which would
interfere with the operation of the appliance.
Important
When operating the tumble dryer, the room
temperature must not exceed 35°C, as it may affect
the performance of the appliance.
Stacking kit
A special stacking kit is available through your
dealer, to enable the mounting of the dryer on top of
your washing machine.
Electrical connection
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
The manufacturer declines any liability
should this safety measure not be observed.
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the
appliance’s rating plate. (See picture on page 4).
The appliance is supplied with a 13amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 13amp ASTA approved (BS1363A) fuse
must be used.
Should the plug need to be replaced for any reason,
proceed as described below.
P1044
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow
- Earth
Blue
- Neutral
Brown
- Live
The wire coloured green and yellow must be
connected to the terminal marked with the letter «E»
or by the earth symbol
or coloured green and
yellow.
The wire coloured blue must be connected to the
terminal «N» or coloured black.
The wire coloured brown must be connected to the
terminal marked «L» or coloured red.
Upon completion there must be no cut, or stray
strands of wire present and the cord clamp must be
secure over the outer sheath.
WARNING:
A cut off plug inserted into a 13 amp socket
is a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safely.
Permanent connection
In the case of permanent connection it is necessary
that you install a double pole switch between the
appliance and the electricity supply (mains), with a
minimum gap of 3mm between the switch contacts
and of a type suitable for the required load in
compliance with the current electrical regulations.
The switch must not break the yellow and green earth
cable at any point.
GREEN & YELLOW
BROWN
CORD CLAMP
BLUE
13
A
P1041
E
N
L
125994640.qxd 09/05/01 16.07 Pagina 15 (Nero/Process Black pellicola)