www.zanussi.com
8
Features and characteristics
This appliance provides you with instant hot water
after opening water outlet valve, there for it is
sufficient for all home use purposes that requires hot
water. this appliance contains the following features:
Low pressure start up ,which make it suitable for
user living in high level floors that suffers low water
pressure.
Forced shut off in case of flames extinguishing to
prevent gas leakage.
Anti-Blast on start up.
High pressure(over 8bar) protected.
When this feature is activated, the high
pressure relief valve will leak water to ambient in
form of water drops to relief pressure inside the
appliance.
Over heating protection, prevents water
temperature to increase above standard
temperature whatever the overheating cause is.
When this feature is activated, the high
temperature cut-off thermostat will force shut-off
to the gas valve to prevent over heating from
evaporating water inside appliance to protect the
user and the appliance .
Back wind protection to insure normal operation in
existence of wind back flow.
Continuous operation for only 20 minutes ,to
protect from exhaust accumulation, and in case of
forgot water valve open while water source is cut
and back again.
Care and cleaning
All the repair and maintenance must be carried out
by customer service authorized technicians.
Normally the batteries should be replaced once half
a year.
appliance malfunctions should be repaired on its
time to keep the performance of it.
A periodical check and maintenance of the
appliance recommended to be fulfilled every 6
months.
A clean and wet cloth can be used for the cleaning
of the heater. dissolvent products are not allowed
for the cleaning!
Caution!
Please only clean exhaust pipe in cold
state!
What to do if.....
Certain problems are due to lack of simple maintenance or oversights, which can be solved easily without calling
the service technicians, before contacting the local service center please carry out the check listed below.
Problem
Problem cause \ Solution
Flames extinguishing while use
Low gas pressure
o
Check gas connection then open gas valve
Low inlet water pressure
o
Check water supply main pressure
Safety feature activated(20 minutes of use shut-off timer)
o
Re-start the appliance (close outlet water valve and re-open)
Low battery
o
Replace batteries
Strong wing outside
o
Wait until wind stop