background image

www.zanussi.com

 

 

 

 

Features and characteristics 

 

This appliance provides you with instant hot water 
after opening water outlet valve, there for it is 
sufficient for all home use purposes that requires hot 
water. this appliance contains the following features: 

 

Low pressure start up ,which make it suitable for 
user living in high level floors that suffers low water 
pressure. 

 

Forced shut off in case of flames extinguishing to 
prevent gas leakage. 

 

Anti-Blast on start up. 

 

High pressure(over 8bar) protected. 

 

        When  this  feature  is  activated,  the  high 
pressure  relief  valve  will  leak  water  to  ambient  in 
form  of  water  drops  to  relief  pressure  inside  the 
appliance. 

 

Over heating protection, prevents water 
temperature to increase above standard 
temperature whatever the overheating cause is. 
        When  this  feature  is  activated,  the  high 
temperature  cut-off  thermostat  will  force  shut-off 
to  the  gas  valve  to  prevent  over  heating  from 
evaporating  water  inside  appliance  to  protect  the 
user and the appliance . 

 

 

Back wind protection to insure normal operation in 
existence of wind back flow. 

 

Continuous operation for only 20 minutes ,to 
protect from exhaust accumulation, and in case of 
forgot water valve open while water source is cut 
and back again. 

 

Care and cleaning

 

 

All the repair and maintenance must be carried out 
by customer service authorized technicians. 

 

Normally the batteries should be replaced once half 
a year. 

 

appliance malfunctions should be repaired on its 
time to keep the performance of it. 

 

A periodical check and maintenance of the 
appliance recommended to be fulfilled every 6 
months. 

 

A clean and wet cloth can be used for the cleaning 
of the heater. dissolvent products are not allowed 
for the cleaning! 

 

        

Caution! 

Please only clean exhaust pipe in cold 

state! 

 

 

 

What to do if.....

 

Certain problems are due to lack of simple maintenance or oversights, which can be solved easily without calling 
the service technicians, before contacting the local service center please carry out the check listed below. 

Problem 

Problem cause \ Solution 

Flames extinguishing while use 

 

Low gas pressure 

o

 

Check gas connection then open gas valve 

 

Low inlet water pressure 

o

 

Check water supply main pressure 

 

Safety feature activated(20 minutes of use shut-off timer) 

o

 

Re-start the appliance (close outlet water valve and re-open) 

 

Low battery 

o

 

Replace batteries 

 

Strong wing outside 

o

 

Wait until wind stop 

Summary of Contents for Gas Water Heater 10 liter

Page 1: ...User manual Gas Water Heater 10 liter ...

Page 2: ...ct the service center Never remove or damage stickers warning labels or nameplates attached to the appliance General safety Make sure that gas type used id identical to the type specified on the nameplate It is dangerous to alter the specifications or attempt to modify this product in any way unless through service center or natural gas accredited companies No touches on hot parts of the heater su...

Page 3: ...ter away from heat sources such as gas cockers The heater must be installed onto a vertical wall in a correct vertical way Usage This appliance is designed for domestic use It must not be used for purposes other than those for which it was designed During operation do not put any inflammable or such materials close to the appliance In case of gas smell o Close the gas valve o Open all the windows ...

Page 4: ...ontrol water flow rate on Min position it decreases the water flow to the minimum level and start up pressure to the minimum and on Max it increase water flow to the maximum and start up pressure to the maximum Gas Control knob Used to control gas flow rate on Min position it decreases the gas flow to the minimum level and on Max it increase gas flow to the maximum Digital Display Operates only wh...

Page 5: ...n eyes level about 140 to 160 cm The space of exhaust pipes from ceiling should be not less than 60cm and from side walls not less than 30cm Caution The appliance should be equipped with an exhaust pipe or a chimney Please pay attention to the specific regulations for installation required by the local country Caution make sure not to mount the appliance on a wall contains inflammable materials if...

Page 6: ...lation check the gas connection with soap foam for leakage use the appliance only when leakage free and passed the inspection by local gas administrative institution Batteries installation Put two D size batteries 1 5 Volt into the battery box make sure of the polarity order and close the box Exhaust pipe installation This appliance has an upper opening for exhaust connect it with an external pipe...

Page 7: ...ition it will work all flam rows Temporary shutdown When hot water temporary not needed during use just turn off the hot water valve when hot water needed again turn on the hot water valve again Caution Be careful water temperature may be too high at the moment the water flow resumes Caution If not using for long period close water and gas supply and remove batteries Caution Be careful water tempe...

Page 8: ...peration for only 20 minutes to protect from exhaust accumulation and in case of forgot water valve open while water source is cut and back again Care and cleaning All the repair and maintenance must be carried out by customer service authorized technicians Normally the batteries should be replaced once half a year appliance malfunctions should be repaired on its time to keep the performance of it...

Page 9: ...nt ventilation o Remove any air intake blocking stuff from appliance sides Outlet water not hot The gas valve is not completely opened o Open the gas valve completely Flames extinguishing when adjusting water control on Max position Low inlet water pressure o Readjust water control knob towards Min position slightly until problem disappear Technical data Gas Type LPG Rated gas pressure 28mbar Rate...

Reviews: