9
GAS CONNECTIONS
Advice for safety
•
Before installation ensure that the local
distribution conditions (gas type and
pressure) and the pre-setting of the
appliance are consistent.
•
This appliance must be installed only in a
room with good ventilation.
•
This appliance must not connected to a
chimney. It has to be installed and connected
in accordance with the rules in force. Special
attention should be paid to the applicable
disposal concerning ventilation.
•
The adjacent furniture panels have to be heat
proof or protected by such material.
•
The adjusting conditions of this appliance are
mentioned on the rating plate.
Connection to gas supply.
Check that the gas flow and the diameter of the
supply pipe is sufficient to supply all the
appliances of the installation
.
•
Check that all connections are tight.
•
Install an accessible and visible gas tap to
isolate the appliance.
Gas connection
Gas connection must be carried out according to
the rules in force.
Your cooker is delivered adjusted for the kind of
gas stated on the rating plate.
The flexible rubber hose must not be
run across the back of the appliance.
If it is necessary to run the pipework behind the
cooker to reach the gas tap, rigid pipework
should be used which conforms to current gas
regulations.
Rigid Connection
Recommendations when using an appliance
flexible connector are as follows:
- For NATURAL the gas installation pipes to the
termination point shall comply with:
Specification for installation of low-pressure
gas pipe work of up to 20mm (R1) in
domestic premises (2nd family gas) – BS
6891;
power