background image

~ 5 ~ 

 

 
 

1.

 

The CV-117 may not be compatible with the DVI sources and displays that feature resolutions not in the 
aspect ratio of 4:3, 16:9 and 16:10. 

2.

 

All DVI over CAT5 transmission distances are measured using Belden 1583A CAT5e 125MHz LAN cable and 
ASTRODESIGN Video Signal Generator VG-859C. 

3.

 

The transmission length is largely affected by the type of LAN cables, the type of DVI sources, and the type of 
DVI display. The testing result shows solid LAN cables (usually in bulk cable 300m/1000ft form) can transmit 
a lot longer signals than stranded LAN cables (usually in patch cord form). Shielded STP cables are better suit 
than unshielded UTP cables. A solid UTP CAT5e cable shows longer transmission length than stranded STP 
CAT6 cable. For long extension users, solid LAN cables are your only choice. 

4.

 

EIA/TIA-568-B termination (T568B) for LAN cables is recommended for better performance. 

5.

 

To reduce the interference among the unshielded twisted pairs of wires in LAN cable, you can use shielded 
LAN cables to improve EMI problems, which is worsen in long transmission. 

6.

 

Because the quality of the LAN cables has the major effects in how long transmission distance will be made 
and how good is the received display, the actual transmission length is subject to your LAN cables. For 
resolution greater than 1080i or 1280x1024, a CAT6 cable is recommended. 

 

Performance Guide for DVI over LAN Cable Transmission 

Performance rating 

Type of LAN cable 

Wiring 

Shielding 

CAT5 

CAT5e 

CAT6 

Solid 

Unshielded (UTP) 

 

 

 

Shielded (STP) 

 

 

 

Stranded 

Unshielded (UTP) 

 

 

 

Shielded (STP) 

 

 

 

Termination

 

Please use 

EIA/TIA-568-B

 termination (

T568B

) at any time 

 

Notice

 

Reviews: