background image

CUSTOMER

SUPPORT

INFORMATION

Order 

toll-free

in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 

877-877-BBOX

FREE technical support, 24 hours a day, 7 days a week: Call 

724-746-5500

or fax 

724-746-0746

Mail order:  

Black Box Corporation

, 1000 Park Drive, Lawrence, PA 15055-1018

Web site: 

www.blackbox.com

•   E-mail: 

[email protected]

MARCH 2000

LR0005A-KIT

LR0010A-KIT

LR0006A-AC

LR0011A-AC

LR0006A-DC

LR0011A-DC

LR0007A

LR0012A

IDSL and SDSL Network Extenders

IDSL Network Extender - Provider Unit - 12 Port - 

AC

 1     2   

 3    4    

5     6

CONFIGURA

TION

 7    8    

9   10  1

1 12

WAN

RX
TX

LNK

1

ETHERNET

IDSL

2 3

4 5

6 7

8 9 10

11 12

PWR

Summary of Contents for LR0005A-KIT

Page 1: ...46 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com MARCH 2000 LR0005A KIT LR0010A KIT LR0006A AC LR0011A AC LR0006A DC LR0011A DC LR0007A LR0012A IDSL and SDSL Network Extenders IDSL Network Extender Provider Unit 12 Port AC 1 2 3 4 5 6 CONFIGURATION 7 8 9 10 11 12 WAN RX TX LNK 1 ETHERNET IDSL 2 3 4 5 6 7 8 9 10 11 12 PWR ...

Page 2: ......

Page 3: ...ed to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult an experienced radio TV technician for help Caution Changes or modifications not expressly approved by the party r...

Page 4: ...7 El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación Todo otro servicio deberá ser referido a personal de servicio calificado 9 El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso L...

Page 5: ...r una antena externa deberá ser localizada lejos de las lineas de energia 16 El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación 18 Servicio por personal calificado deberá ser provisto cuando A El cable de poder o ...

Page 6: ...4 IDSL AND SDSL NETWORK EXTENDERS TRADEMARKS USED IN THIS MANUAL Any trademarks mentioned in this manual are acknowledged to be the property of the trademark owners ...

Page 7: ...IDSL Bandwidth 8 2 4 Selecting SDSL Bandwidth 9 2 5 LEDs 9 3 Installation 13 3 1 Installation for LR0005A KIT LR0007A LR0010A KIT and LR0012A 13 3 2 Installation for LR0006A AC DC and LR0011A AC DC 14 Appendix Port Pinouts 17 A 1 LR0005A KIT LR0007A LR0010A KIT and LR0012A 17 A 2 LR0006A AC DC and LR0011A AC DC 17 ...

Page 8: ... All IEEE 802 3 Ethernet 10BASE T LR0005A KIT LR0007A LR0010A KIT LR0012A RJ 45 LR0006A LR0011A 12 RJ 21 SDSL Interface All 2B1Q Encoding LR0005A KIT LR0007A RJ 45 LR0006A RJ 21 50 pin telco Indicators Connection Power Collision TX RX Link Power LR0005A KIT LR0006A AC LR0007A LR0010A KIT LR0012A LR0011A AC 100 120 VAC 60 Hz LR0006A DC LR0011A DC 40 56 VDC Positive Ground Size LR0005A KIT LR0007A L...

Page 9: ...AC DC is a 12 port Provider unit with 12 individual IDSL to Ethernet ports to which you can attach 12 Subscriber units No bridging or routing is done internally The LR0012A is a single IDSL to Ethernet Subscriber unit The connection across the SDSL line may be at 272 528 or 728 kbps or 1 168 Mbps in both directions Connection across the IDSL line may either 144 or 128 kbps Speed is selectable and ...

Page 10: ...ubscriber Units The units will build a database up to 255 MAC addresses and will provide traffic filtering based on the learned MAC addresses MAC addresses are learned based on the Source Address of the Ethernet packets and are filtered based on the Destination Address of the Ethernet packets Addresses are removed from the filtering database if the unit does not receive traffic from that Source fo...

Page 11: ...007A SDSL LED Pulsing green once per second indicates that the SDSL connection is operational and the unit is receiving either valid data packets or status packets from the remote unit on the other side of the SDSL connection Power Steady green indicates normal operation Collision Flashing red indicates collision on Ethernet segment Rx Flashing amber indicates data received from Ethernet segment S...

Page 12: ...ent NOTE The SDSL connection may take several minutes to establish full connectivity at the desired bandwidth setting During connection setup the SDSL line will come up briefly indicated by WAN LED but will then shut down and retrain at the appropriate bandwidth setting indicated by the front panel switches Once the connection has been established the WAN LED will function as described above LR000...

Page 13: ...ent NOTE The SDSL connection may take several minutes to establish full connectivity at the desired bandwidth setting During connection setup the SDSL line will come up briefly indicated by IDSL LED but will then shut down and retrain at the appropriate bandwidth setting indicated by the front panel switches Once the connection has been established the IDSL LED will function as described above LR0...

Page 14: ...DSL Network Extender on the opposite side of the link or valid data packets across the link Power Steady green indicates normal operation Collision Flashing red indicates collision on Ethernet segment Rx Flashing amber indicates data received from Ethernet segment Tx Flashing amber indicates data transmitted to Ethernet segment Lnk Steady green indicates that an Ethernet link has been established ...

Page 15: ...D is lit On the IDSL Network Extender and SDSL Network Extender Provider Units the Lnk Tx and Rx LEDs will also be lit 3 Plug in the DSL connection see the Appendix for SDSL connection pinout information On the Provider Units verify that the switches on the back of the unit are in the appropriate position see below LR0010A Kit Provider Unit Switch Configuration Switch 1 Not used Switch 2 Bandwidth...

Page 16: ...both DSL and Ethernet link on both sides of the connection normal data communication will flow through the units essentially providing a very long Ethernet connection at DSL speeds 3 2 Installation for LR0006A AC DC and LR0011A AC DC 1 Unpack the Network Extender and power cord AC only Attach the included rubber feet for stackable installations or attach rackmount brackets and mount the Network Ex...

Page 17: ... breakout cable see the Appendix for SDSL connection pinout information 4 Verify that the switches on the front of the unit are in the appropriate position for each port see below LR0011A AC DC Switch Configuration per port pairing Switch 1 Not used Switch 2 Bandwidth Distance in feet Down 144 kbps 18 000 Up 128 kbps 18 000 LR0011A AC DC Switch Configuration per port pairing Distance Supported in ...

Page 18: ...the front of the unit See the Appendix for Ethernet connection pinout information NOTE The Network Extender Provider Units do not present Ethernet link Lnk to the Ethernet network equipment if the DSL connection is not present This feature allows for remote monitoring of the DSL line by simply monitoring the Ethernet port for link status Once the units have established both DSL and Ethernet link o...

Page 19: ...n 6 TX Pin 6 Pin 7 Pin 7 Pin 8 Pin 8 A 2 LR0006A AC DC and LR0011A AC DC Ethernet RJ 21 SDSL or IDSL RJ 21 Port Pin Port Pin 1 26 TX1 1 26 Tip 1 TX1 1 Ring 27 RX1 2 27 Tip 2 RX1 2 Ring 2 28 TX2 3 28 Tip 3 TX2 3 Ring 29 RX2 4 29 Tip 4 RX2 4 Ring 3 30 TX3 5 30 Tip 5 TX3 5 Ring 31 RX3 6 31 Tip 6 RX3 6 Ring 4 32 TX4 7 32 Tip 7 TX4 7 Ring 33 RX4 8 33 Tip 8 RX4 8 Ring 5 34 TX5 9 34 Tip 9 TX5 9 Ring 35 R...

Page 20: ... Port Pin Port Pin 10 RX5 10 Ring 6 36 TX6 11 36 Tip 11 TX6 11 Ring 37 RX6 12 37 Tip 12 RX6 12 Ring 7 38 TX7 13 TX7 39 RX7 14 RX7 8 40 TX8 15 TX8 41 RX8 16 RX8 9 42 TX9 17 TX9 43 RX9 18 RX9 10 44 TX10 19 TX10 45 RX10 20 RX10 11 46 TX11 21 TX11 47 RX11 22 RX11 12 48 TX12 23 TX12 49 RX12 24 RX12 ...

Page 21: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 2000 Black Box Corporation All rights reserved ...

Reviews: