The method of grounding

Pressure release valve:

• Installation of the Pressure release valve is used to prevent the temperature or 
pressure going too high inside the tank. When the temperature or pressure reaches 
the set value, the valve will open automatically so as to force the pressure or 
decrease the temperature. 

• The handle of the safety valve should be pulled once every six months so as to 
remove the calcium carbonate deposition decrease the temperature. Take care as 
the temperature of the discharging water is very high.     

• Vent pipes should be thermally insulated to prevent the pipes freezing in the 
winter.      

REMARK 

Pressure release valve: Model: YA-20, action pressure:0.7MPa  

WARNING  

Fail to operate the relief valve easing gear atleast once every six months 

mayresult in the appliance exploding. Continuous leakage of water from the valve 
may indicates problem with the appliance.

Matters for attention 

Power connection 
must have good earthing!

L1

L2

Cable

24

Summary of Contents for HOTSPRING HSHPM300

Page 1: ...HOTSPRING HEAT PUMP WATER HEATER manual Scan to download HSHPM300 ...

Page 2: ...Please read this manual carefully before installation Whats in the box 1 X Water Tank 1 X Pressure release valve 1 X PVC Drain pipe 4 X Screws 1 X Cable Gland ...

Page 3: ...tallation instructions How to install Cables and power chords Using the APPLIANCE Repairs and maintenance Transportation matters for attention warranty Certifications index 1 5 6 9 11 12 2o 22 23 26 Heat Pump Water Heater is referred to as Appliance ...

Page 4: ...f an electric water heater and can be installed in locations which are unsuitable for solar hot water heating Safe and Environment Friendly Produces no harmful gases and has no open flame Making the appliance safe to work with when installing Easy to Operate Featuring an easy to use controller to set the desired water temperature 1 CHARACTERISTICS Air Inlet Air Outlet ...

Page 5: ...2 dimensions here s a little info about the appliance Hot water outlet Cold water inlet 640 mm 1955 mm 98 5 mm 1195 mm ...

Page 6: ...unning Current including back up heater Voltage and Frequency 230V Others Refrigerant type Sound power level Coefficient of performance Air Volume Re heat time in HP Mode 35 degrees delta Hot water generation per hour Hp Mode 35 degrees delta Heat Up Delta per hour Heat Pump Mode Heat Up Delta per hour with Back Up IP Rating Compressor Brand Compressor Type 300 Litre 640 mm 129 kg 429 kg 1995 mm E...

Page 7: ...in liquid again This liquid passes to the expansion valve where the temperature drops and refrigerant can absorb heat again This liquid passes to the expansion valve where the temperature drops and refrigerant can absorb heat again The appliance has a freeze protection system The freeze protection system will protect the water heater from damage by preventing ice forming in the waterways of the wa...

Page 8: ... result in invalidation of the warranty If the supply cord is damaged please ask for replacement as it must be replaced in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a per...

Page 9: ... that the appliance and power connections have a good earthing connection Failure to do this may cause an electrical shock CHECK DRAINAGE FITTINGS Before installation make sure there are no leakages in the drainage fittings ISOLATING SWTICH This appliance requires an isolating switch as required by local by laws INSTALLATION LOCATION The appliance cannot be installed next to a flame flammable gas ...

Page 10: ...nce can be installed Indoor or Outdoor The applaince has to be installed with ventilation if its installed indoor Air outlet Ventilation Ventilation Ventilation Ventilation Barrier Unit mm Before you install the Appliance INDOOR Installation SPace Closed Area Closed Area Display 500 1000 300 1000 600 500 7 ...

Page 11: ...pliance 8 600 mm OUTDOOR Installation SPace It is recommend to cover the appliance if its installed outdoor Installing the appliance under a Chajja or protection roof will help in prolonging the life of the appliance s internal working system ...

Page 12: ...e deposits and verify that it is not blocked A discharge pipe connected to the pressure relief device is to be installed in a continuously downward direction and in a frost free environment Facilities for draining and filling of systems shall be provided where these are required for servicing purposes The drainage facilities shall be fit at the lowest point in the closed circuit Seismic restraints...

Page 13: ...alve connecting thread is BSP3 4 internal thread After installation it must be confirmed that the drainpipe outlet is exposed in the air Drainpipe is joined to the pressure relief orifice of this valve you must ensure that the flexible drainpipe is exposed in the air The Pressure release valve attached with the appliance must be installed Failure to do so will cause damage to the appliance and pos...

Page 14: ...noise switch the power off and consult your service provider If the power cord is damaged It must be replaced by a qualified electrician Make sure that the parameters have been pre set to a temperature of 60 degrees INSPECTION BEFORE TRIAL RUNNING Check the water supply to the tank and pipe connections for possible leaks Check that all power connections are secure before switching on 11 ...

Page 15: ...WHEN USING THE appliance Make sure you follow the following precautions 12 ...

Page 16: ...n on off the unit Switch unit running modes or save setting parameters Set the clock or the timer Turn on off the electric heater or switch fan modes Move up or increase parameter values Move down or decrease parameter values Clock Main display area Auxiliary display area WHEN INSTALLING THE appliance 13 ...

Page 17: ... area displays the minute Second Shows that the main display area displays the second Centigrade Shows that the temperature in Main display area or Auxiliary display area is in Fahrenheit Shows that the temperature in Main display area or Auxiliary Shows that the keyboard is locked display area is in Parameter setting Shows that the parameter is adjustable Lock STATUS ICON MEANING Standard Heating...

Page 18: ...f the wire controller to turn on the appliance and at this time the main display area shows the water outlet temperature Press and hold for 0 5s in the running interface of the wire controller to turn off the appliance and at this time the main display area shows OFF NOTE The ON OFF button can only be used to turn on off the appliance in standby or running interface of the wire controller WHEN INS...

Page 19: ...liance and electric heating to heat at the same time At the beginning only the appliance operates After the appliance operates for a certain time 200minutes if the target temperature has not been reached the electric heater will operate If the water temperature reaches target temperature electric heater will not operate Eco Heating Mode Appliance only operates on Eco Heating Mode The electric heat...

Page 20: ...menu by timeout and the changes are confirmed Example Change the target temperature from 50 to 55 5 when the actual outlet water temperature is 18 Outlet water temperature Time Target temperature Press or again to change the target temperature Press to confirm or to cancel then return to the previous interface Press once or to check the target temperature NOTE Make sure that the temperature of the...

Page 21: ...ppliance target temperature is reached Definition of the fan icon 1 Running shows that the fan is running at high speed 2 Running shows that the fan is running at low speed 3 Fan icon disappears shows that the fan is shut off 4 Static shows that the fan will run at high speed when target setting temperature is reached 5 Static shows that the fan will run at low speed when target setting temperatur...

Page 22: ...Keyboard locking Press and hold for 5s once to lock the keyboard Press and hold for 5s again to unlock the keyboard Press and hold for 5s Lock icon WHEN INSTALLING THE appliance 19 ...

Page 23: ...ppliance needs to be relocated repaired or installed again only use a Zanskar certified technician PROHIBITED We strongly advice customers to not try and repair the applaince This may cause serious injury and or damage to the appliance OPERATION ATTENTION SHUT OFF THE POWER Turn off power before cleaning maintenance repair 20 ...

Page 24: ...tion The suction pressure is low Low pressure switch action No water or little water in water system Wired remote control with master signal failure Ambient temperature is too low Water flow volume not enough Water system pressure difference is small Water flow volume not enough Water system pressure difference is small Check or change the water bottom temp Sensor Check or change the water top tan...

Page 25: ...he appliance must remain mounted on the pallet The lifting rate should be kept to a minimum Due to its top heaviness the appliance must be secured against tipping over To prevent any damage the appliance must be placed on a level surface Transporting it manuall y For manual transport the wooden pallet can be used for the bottom part Using ropes or carrying straps a second or third handling configu...

Page 26: ...n the appliance and orient it or provide tubing so that any discharge from the valve exits only within 6 inches above or at any distance below the structural floor and does not contact any live electrical part The discharge opening must not be blocked or reduced in size under any circumstances Hydrogen gas is produced in a hot watersystem served by this appliance that has not been used for along p...

Page 27: ...onths so as to remove the calcium carbonate deposition decrease the temperature Take care as the temperature of the discharging water is very high Vent pipes should be thermally insulated to prevent the pipes freezing in the winter REMARK Pressure release valve Model YA 20 action pressure 0 7MPa WARNING Fail to operate the relief valve easing gear atleast once every six months mayresult in the app...

Page 28: ...e tank will be drained out through the drain outlet Use of the overheating protector DANGER The operation of the thermal cut out indicates a possibly dangerous situation Do not reset the thermal cut out until the appliance has been serviced by a qualified person The overheating protector is used to turn the power off preventing the water from being heated too high To return the appliance to its no...

Page 29: ... intervention Inspection report of the Zanskar s authorised technician will be treated as final and binding under the warranty for determining the defects repairs alterations required or carried out or certifying working of the goods thereafter The customer will have no claim under this warranty in respect of personal injury damage or property or consequential damages or for utilisation of the goo...

Page 30: ...ndards WaterMark Certificate of Conformity Level 1 AS 3498 2009 Authorization requirements for plumbing products Water heaters and hot water storage tanks StandardsMark License AS NZS 2712 2007 Solar and heat pump water heater design construction 27 ...