3.8 Drain hoses installation
NOTE
For proper drainage, the drain hose must slope down continuously from the evaporators
to the wall drains with no kinks or droop.
NOTE
It is recommended routing each individual drain hose directly out of the cold storage to
allow faster water drainage.
To install the drain hoses, proceed as follows:
Insert the entire length of the resistance wire into the drain hose (if present).
CAUTION
Do not cut the resistance wires.
Attach drain hose to evaporator drain outlet (1, Figure 34) and fix with the supplied clamps.
Fix drain hose to the outside of the cold storage wall with supplied clamps and screws.
Seal the piping passageways hole with mastic to avoid infiltration.