_________________________________________________________________5. WORKING
____________________________________________________________________________
18
CITIZEN 6 - 9/MC, CITIZEN 6+6 - 9+9/MC ELECTROMECHANICAL VERSION
5.2.4 Temperature control
Baking chamber temperature
display
In the normal operation mode, this display shows the cooking chamber
temperature in °C.
In the temperature programming mode, this display shows the programmed
temperature. This displays is also used to display some failures (5.3).
5.2.5
Set button,
Push-button of ESC (vers. TERM0012)
Press two times this button
to select the temperature programming
mode.
WARNING ! do not keep this button pressed because this might alter
the thermostat internal parameters and cause possible unpredictable
failures.
In this operation mode, the
display shows the programmed
temperature, which can be changed using the
and
buttons. If no
buttons are pressed for more than 3 seconds, the thermostat automatically
returns to the normal operation mode. See chapter 8 for the range of
temperatures that can be selected.
To press two times this push-button
in order to exit from the way
programming temperature.
5.2.6
Button of SET and of ESC (vers. TERM0060)
To press once this button
to select the temperature programming
mode.
WARNING !
do not keep this button pressed because this might alter
the thermostat internal parameters and cause possible unpredictable
failures.
In this operation mode, the
display shows the programmed
temperature, which can be changed using the
and
.
buttons. If
no buttons are pressed for more than 15 seconds, the thermostat
automatically returns to the normal operation mode. See chapter 8 for the
range of temperatures that can be selected.