_______________________________________________________________5. INSTALLATION
______________________________________________________________________________
14
CITIZEN 6 - 9/MC
5.4.Mounting the module
steam outlet
electrical cable input
Fig. 5.3.Position of electrical cable input, steam outlet and plate.
Position the modules one above the other in the right order ( prover or base,
baking module, hood) and fix by means of the accompanying hooks and
screws.
5.5.Connecting the steam outlet
The steam outlet should be connected thought the duct on the hood (see
instructions). It is necessary to use a pipe Ø200 mm connected to the
outside.
Avoid long horizontal stretches as they may lead too accumulations of
condensation and possible dripping.
For the exact connection position see Figure 5.3.
a mm
b mm c mm
w mm
Citizen
6/MC
740 630 733 1370
Citizen 9/MC
740
630
1083
1370