14
Electrical installation
The electricial installation may only be
performed by an authorised fully
trained electrician. The electrical
installation must be carried out in
accordance with prevailing regulations
for appliances using heavy current.
The installation must comply with any
specific requirements specified by the
local electricity supply authority.
There must be no interference with any
of the unit´s electrical parts.
The factory´s guarantee is rendered
null and void in cases of faulty
connection and in cases of interference
with the unit´s electrical parts.
Single-phase zero-earth
(min. 16A)
Cable type 1 mm2 HO5VV-F
The cable´s outside diameter must be
between 7,5 and 10,5 mm.
The cable is mounted in teh pegs as
shown.
Unscrew the couver knob while
connecting the cables. A unit is led
directly to the power point or the outlet
rose.
The range must be connected via an
external switch wiht a contact
separation of at least 3 nmm in each
pole.
Cover hood