This charger is designed for indoor use only and should never be exposed

to rain.

Do not disassemble the controller. Take to a qualified person if the unit

requires repairing.

Lead acid, LiFePO4, LTO batteries can be dangerous. Ensure no sparks or

flames are present when working near batteries.

Eye protection should always be used. Never short circuit the battery

Given sufficient light solar panels always generate energy even when they

are disconnected.

Accidental ‘shorting’ of the terminals or wiring can result in sparks causing

personal injury or a fire hazard. We recommend that you cover up the

panel(s) with some sort of soft cloth so you can block all incoming light

during the installation. This will ensure that no damage is caused to the

Solar Panel or Battery if the wires are accidentally short circuited.

Always install a battery fuse on each circuit including the solar controller

Do not reverse connect the wires to the solar panel or battery

WARNING – IMPORTANT PLEASE READ

MOUNTING THE DEVICE

The Solar Controller has two mounting options.

1. Surface mount:

The quickest and easiest way to mount the unit is to use the two plastic

spacers and self tapping screws supplied and mount the unit to a flat surface,

2. Flush (panel) mount:

Before deciding to use this mounting method, please ensure there is sufficient

depth behind the controller or in the cavity. (Refer to Diagram below)

Using the dimensions shown in the following diagram, mark a 105mm x

130mm rectangle where you wish to mount the controller and cut-out the panel

opening then use the two self- tapping screws supplied to secure the unit.

Summary of Contents for ZS-30A

Page 1: ...1 Solar Controller Battery Charger ZS 30A ZS 40A Input DC12V Solar panel Max 25V Output DC 12V 30A ZS 30A DC 12V 40A ZS 40A User s Manual...

Page 2: ...p charging when the battery is full and will automatically start charging the battery as required This process will also reduce water loss and help prevent the battery from drying out Protects your ba...

Page 3: ...ill ensure that no damage is caused to the Solar Panel or Battery if the wires are accidentally short circuited Always install a battery fuse on each circuit including the solar controller Do not reve...

Page 4: ...lied crimp the terminals on your Solar Array wires and connect to the Solar Panel like shown 2 Using the Terminals supplied crimp the terminals on your Battery wires and connect to the Battery like sh...

Page 5: ...e LCD displays the charging statues as below Press VOLT AMP button in sequence the LCD will display in turn with Battery Voltage Charging Current Charged capacity Amp hour and Battery Temperature if e...

Page 6: ...acid battery GEL AGM WET battery has a voltage of more than 13 6 Volts A fully charged LiFePO4 or LTO battery has a voltage level of 13 4V The 6 LED s indicate the charging status and the battery cond...

Page 7: ...ontroller provides two optional devices excludes in the packaging box Optional external Battery temperature sensor As an option the unit provides a port to connect the external battery temperature sen...

Page 8: ...attery Battery voltage discharged to less than 10 0 2 VDC Automatic equalizing charging periodical 28 Day 2 8 Equalization charging voltage at 25 15 5 0 2 VDC 2 9 Equalization charging timer timed out...