This solar controller provides multiple charging stages with smart charging algorithm. 

For Lead acid battery (Crystal, Gel, AGM, WET and Calcium battery):

Soft Charge – Bulk Charge - Absorption charge - Equalizing Charge* - Float charge

For Lithium battery (LCO, LI-95, LFP, LTO battery)

Soft Charge – Bulk Charge - Absorption charge – Stop and Restart charge*

Soft start -

 When batteries suffer an over-discharge, the controller will softly ramp the battery 

voltage up to 10V. 

 

Bulk Charge -

 Maximum current charging until batteries rise to Absorption level. 

For Lead crystal 

battery type

, the charge controller will deliver two step level of Bulk charge, when the first level 

rises the battery voltage up to 14.4V, then switch into the second level of the 10% of the first bulk 

charge rate, until the Lead crystal battery voltage up to 14.7V. 

 

Absorption -

 Constant voltage charging and battery is over 85% for lead acid battery; the Lithium 

battery (LCO, LFP and LTO battery) will close fully charged after absorption stage, for LI-95 Lithium 

battery will be charged 95% Capacity. 

 

Equalization *

 - Only for WET or Calcium battery type, when the battery is deeply drained below 

10V or every 28 days cycle, it will automatically run this stage to bring the internal cells as an equal 

state and fully complement the loss of capacity. (Lead crystal, Gel, AGM battery or Lithium 

batteries do not run Equalization charge) 

Float Charge or Re-Start charge* -

 Battery is fully charged and maintained at a safe level.

A fully charged Lead acid battery (Crystal, GEL, AGM, WET or Calcium battery) has a voltage of 

more than 13.6 Volts; if the lead acid battery voltage drops to 12.7V at float mode, it will return to 

Bulk charge, Lithium battery will stop charge after Absorption stage, it will restart to bulk charge if 

the voltage discharge less than 12.0V for LCO battery, 13.0V for LTO battery, 13.3V for LFP or LI-95 

battery.  

 

Remarks -

 This controller provides an override function (force output delivery) for some heavily 

discharged Lead acid batteries (Low to 0V), or for some LiFePO4 batteries which are protected by 

BMS due to over-discharged. Press 

BATT / -

 button for 3 seconds to wake up the Lithium battery 

(activate the BMS against protection) or override the Lead acid battery.

CHARGING STAGE

TECH SUPPORT

541-728-0924

[email protected]

Summary of Contents for DOMETIC SCC1012

Page 1: ...LER USER MANUAL TECH SUPPORT 541 728 0924 support zampsolar com INPUT DC 100V MAXIMUM OUTPUT DC 12V 24V 30A THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS PLEASE READ AND FOLLOW INSTRUCTIONS TO ENSURE PROPER OPERATION ...

Page 2: ...Designed according to UL1741 EN IEC 62109 1 EMI standard EN61000 61 EN61000 63 and FCC standard 47 CFR Part 15 Subpart B This charger is designed for indoor use only and should never be exposed to rain Do not disassemble the controller Contact Zamp Solar support if the unit requires attention Lead acid LCO LiFePO4 LTO LI 95 batteries can be dangerous Ensure no sparks or flames are present when work...

Page 3: ... SUPPORT 541 728 0924 support zampsolar com The Solar Controller should be mounted using the mount points highlighted in red shown in the image below Mount the unit to a flat surface MOUNTING THE CONTROLLER ...

Page 4: ...G Rated Current 30 Amp Solar Panel Controller Battery Solar Panel Controller Battery meter Rated Current Total cable length 10FT 10FT 10AWG 10 15FT 10 15FT 8AWG 20FT 20FT 6AWG Total cable length Total cable size AWG Rated Current 30 Amp Solar Panel Controller Battery Solar Panel Controller Battery meter 1 Take off the rubber mask plate at OPEN end on the top face you will see the four screws loose...

Page 5: ...he SET UP button again to confirm the absorption duration setting then move to next Equalization voltage setting Alternatively display Equalization voltage character EqL U and voltage data Equalization voltage setting range from 13 20V 16 2V press PV or BATT button for once 0 05V variation press the SET UP button again to confirm the Equalization voltage and then move to next Equalization duration s...

Page 6: ...city Equalization Only for WET or Calcium battery type when the battery is deeply drained below 10V or every 28 days cycle it will automatically run this stage to bring the internal cells as an equal state and fully complement the loss of capacity Lead crystal Gel AGM battery or Lithium batteries do not run Equalization charge Float Charge or Re Start charge Battery is fully charged and maintained...

Page 7: ...BLUE FLASH ON ON OFF SOFT START BULK CHARGE FLOAT CHARGE ABSORBTION EQUALIZATION SOLAR PANEL ABNORMAL MODE BATTERY ABNORMAL MODE SOLAR PANEL WEAK 15V Solar panel is connected battery disconnected SOLAR PANEL REVERSE CONNECTION Battery reverse connection SOLAR PANEL OVER VOLTAGE 95V Battery over voltage than 17V Battery temperature over 65ºC The controller over temperature protection LCD DISPLAY LC...

Page 8: ... Equalization Charging Voltage at 25ºC Input Output Terminal Controller Material Operating temperature Mounting Storage temperature IP grade Operating humidity range Net Weight Temperature compensation range Battery temperature compensation coefficient Voltage control accuracy LCO Battery LTO Battery LFP LI 95 battery for CUSTOM setting range Crystal GEL WET AGM and Calcium battery Restart Voltage ...

Reviews: