4
AD/AD-IN/AD-OUT: Audio at the input/output
VD/VD-IN/VD-OUT: Video at the input/output
PWR: Power
GND: Ground:
DATA: Communication
NO/COM: Electric trike operation control outputs
KAMERA1/KAMERA2: Extra cameras signal
J4: Power supply socket
Each display with cameras connected to the P4 slot will display
the video from two cameras only (CCTV1 and CCTV2 channels).
The video from the camera connected to the P2 slot will be
displayed on all displays (Doors 2 channel)
Tekst
Translation
PANEL BRAMOWY 1
GATE PANEL 1
ELEKTROZACZEP 1
ELECTRIC STRIKE NO. 1
NIEBIESKI
BLUE
ŻÓŁTY
YELLOW
BIAŁY
WHITE
CZERWONY
RED
PANEL BRAMOWY 1
GATE PANEL 1
Note:
(a) Wiring connection diagram for an entrance panel with electric strike no. 2 + extra external power supply. NC wiring type
(b) Wiring connection diagram for an entrance panel with electric strike no. 1 + extra external power supply. NO wiring type
(c) External power supply port J4 (optional)
(d) Wiring connection diagram for the NC06 gate control module (Connector P3 GND and DATA to NC06; COM NO/NC to gate control)