background image

plik: Instrukcja RTD-01 v1.3 en | modyfikacja: 20.11.2014

USAGE / MOUNTING SAFETY

REGULATOR’S MOUNTING PLACE

CONNECTION DIAGRAM

1   The device should be connected to a single phase in accordance with the standards applicable in the country.  

2  The wiring diagram is specified in this manual instruction.

3  Activities connected with mounting, connection and adjustment should be performed by a qualified electrician, who is familiar with the 

instruction and functions of the device.

4  Casing disassembly will void the warranty and can cause electric shock. 

5  Before mounting, disassembly, cleaning or servicing operations power supply should be switched off from the mains and make sure 

that the connection cables are not under voltage.

6  For mounting a screwdriver with a flat bit with a diameter of 3,5 mm should be used. 

7  Transport, storage and use of the device, in particular mounting of the regulator and the temperature sensor, have an influence on its 

proper operation.

8  Mounting the device in case of lacking of components, device damage or deformation is strongly prohibited.

9  In case of improper operation contact with the producer. 

10 The regulator must not be covered and no elements or items can be hang on it (e.g. a towel).

11 Do not pour any liquids on the regulator.

12 Do not interrupt the power supply of the temperature regulator. It can can cause switching off the backlight of the screen and heating 

control. The entered regulator’s adjustments will be saved.

13 The control and operation of the regulator by children or persons with physical, sensory or mental problems is strongly forbidden.

14 The regulator should be protected from shock and damage.

The regulator is designed to be used in an environment of two degree of contamination, i.e. to be used in domestic conditions 

with standard air circulation.

1  The regulator  should be mounted in a heated room – in a deep junction box ¢60 x 60 mm at a height of 120 cm from the heated 

floor surface.

2  The regulator should be installed in a place not exposed to direct sunlight and in a little airy places.

3  Temperature and humidity in the mounting place should not exceed  values given in technical parameters (0<T<50°C, humidity 

RH > 90%).

L – phase wire

N – neutral wire 

pos.3-4 - loading

pos. 5 – control input (Clock) – function not to be used in case 

of RTD-01

pos. 6-7 – floor sensor

An example of mounting RTD-01 regulator

sunlight

Heating mat

1,2m

Regulator

page: 2

plik: Instrukcja RTD-01 v1.3 en | modyfikacja: 20.11.2014

PROGRAMME SETTINGS

Menu → Programme (Set program day)

. Choose the days of the week the changes will be made for → 

Next

 (by means of 

arrows up / down) set the time and temperature zones). Confirm by 

OK

.

Setting interface; There are 6 periods: morning, leaving home in the morning, returning in the noon, leaving home in the 

afternoon, returning home in the evening and at night. Changes for 7 days can be made at the same time. Grey backlight of the 

days of the week means changes in this operation cannot be made. It can be done after another entry into the Program.

Default settings of a period and temperature are as follows:

ENERGY COST REVIEW

Menu → Energy→ Cost 

and chose an appropriate period on the screen (today, yesterday, current day, current week, current 

month, current year).

 

Choose e.g.

 This week→ Next.

Estimated energy cost will be precise after heating cost adjustment.

ENERGY PARAMETERS SETTING

Menu → Energy→ Load. 

In this interface data can be entered subsequently into

 Load Sett and Tariff Sett → NEXT 

and

 

APPLY. 

In each interface the adjustments should be entered.

TEMPERATURE UNIT SETTING
Menu → Setting → Scale →

 choose 0

°C 

or 0

°F 

and 

Apply

.

SCREEN BACKLIGHT SETTING
Menu → Setting→ Video

. In this interface the preferences should be chosen: background (black or blue), screen brightness 

(3-2-1), stand-by brightness (3-2-1-0), parental control (switch on/switch off). Other functions should be chosen by 

Next 

and at 

the end confirm by 

OK

.

CHOICE OF TEMPERATURE MEASURING METHOD
Menu → Setting → Sensors mode

. One method of measuring and control should be chosen (1. Room, 2. Floor, 3. All)

1. 

Room

; Room sensor (internal); The regulator will read temperature from this sensor and will control the room temperature

2. 

Floor

; External floor sensor (cable with a sensor).The regulator will read floor temperature from this sensor and will control its 

temperature.
3. 

All

; In this system the internal sensor is used to measure and control room temperature and the external sensor protects the 

floor against overheating. If the floor temperature reaches the upper limit,  the regulator will switch off the heating till the floor 
temperature drops beneath the adjusted value.

Days 

of the 

week

Time

Temp.

Time

Temp.

Time

Temp.

Time

Temp.

Time

Temp.

Time

Temp.

All 7

6:00

21 °C

8:00

16,5°C 12:00

21 °C

14:00 16,5°C 18:00

21 °C

22:00 16,5°C

page: 5

plik: Instrukcja RTD-01 v1.3 | mody kacja: 05.04.2016

_

plik: Instrukcja RTD-01 v1.3 | mody kacja: 05.04.2016

_

Reviews: