CONFIGURATION COMMANDS
CONFIG COMMAND
Command
Description
CONFIG
● Configuration of telephone numbers authorized to control the CLIP.
● Configuration of the optional password for controlling text messages.
● Configuration of confirmation.
CONFIG MODE
● Adjusting the device for the remote configuration mode.
CONFIG MODE END
● Deleting the remote configuration mode.
ADD NUM
● Entering additional phone numbers to the list of numbers authorised to control the CLIP. By means of
one commend maximum six numbers can be added every time. Applies to local and remote configura-
tion
DEL NUM
● Deleting a number (s) from the list of telephone numbers authorized to control the CLIP. Every time by
means of one command up to six numbers may be deleted. It refers to local and remote configuration.
ADMIN
● Configuration of telephone numbers authorized to a remote configuration.
INFO
● Configuration of telephone numbers the text messages will be sent to (it refers to the outputs’ status
and occurrences on IN1, IN2 inputs).
RELAY1
● Operation mode configuration for CH1 output.
● Operation mode configuration of CH1 output after power supply voltage is switched off.
RELAY2
● Operation mode configuration for CH2 output.
● Operation mode configuration of CH2 output after power supply voltage is switched off.
MODBUSCONFIG
● Configuration of RS485 transmission parameters for MODBUS protocol.
GATE
● Gate mode configuration.
TASK IN1
● IN1 input configuration.
TASK IN2
● IN2 input configuration.
EF
● Control command configuration for EXTA FREE system.
EF RESET
● Deleting the control command table for EXTA FREE system.
RESET CONFIG
● Restore the default settings (it does not refer to EXTA FREE commands).
CONFIG
<+48tel_1> <+48tel_n>
PASS
<password from 5 to 8 signs>
ACK
<REL1,REL2, REL12>
The maximum of numbers available n = 6
PASS
Keyword - it specifies the password added to the text message during control. The password is added at the beginning of the
message. No parameter means a free access for any number during text message control.
ACK
Keyword - it specifies whether the GRM-10 device must send a confirming text message every time after a specified command
is realised:
REL1
confirmation only for CH1 channel
REL2
confirmation only for CH2 channel
REL12
confirmation for channels CH1 and CH2
<>
No parameter means no confirmation for channels CH1 and CH2
Examples of commands:
Command
Description
4860248600915257
N48602360938, +48600915257 globally released to
control CLIP, no password for text message control, no confirma-
tions for OUT1 and OUT2 outputs.
4860248600915257 ACK REL1
N48602360938, +48600915257 globally released to
control CLIP, no password for text message control, confirmations
only for OUT1 output.
4860248600915257 ACK REL2
N48602360938, +48600915257 globally released to
control CLIP, no password for text message control, confirmations
only for OUT2 output.
4860248600915257 ACK REL12
N48602360938, +48600915257 globally released to
control CLIP, no password for text message control, confirmations
for OUT1 and OUT2 outputs.
4860248600915257 PASS ZAMEL ACK REL1
N48602360938, +48600915257 globally released to
control CLIP, ZAMEL password for text message control, confir-
mations only for OUT1 output.
NOTE: If there is a need to add more authorised numbers to control the CLIP (including control in the gate mode) it can be
done by means of the PC application (telephone section) or the ADD NUM command in configuration mode. It is possible to
enter up to 500 numbers. In order to delete the selected telephone number, use the PC application or the DEL NUM command
in configuration mode.
DEVICE CONTROL
Type of control
Possible control types
Remarks
MANUAL
By means of PK1 / PK2 push buttons on
the front panel
● Bistable ON/OFF
● Time TIME
● Gate GATE
● Times for TIME and GATE modes are adjusted during con-
figuration.
CLIP
By calling to the device
(specified number of signals)
● Bistable ON/OFF
● Time TIME
● Gate GATE
● Times for TIME and GATE modes are adjusted during con-
figuration.
● The number of signals specified during configuration (in
ON / OFF and TIME modes the user must disconnect after
certain number of signals, in the GATE mode the discon-
nection is automatical.
TEXT MESSAGE
By sending a specified message with a
control command to the device
● Bistable ON/OFF
● Time TIME
● Gate GATE
● EXTA FREE control
● Times for the TIME and GATE modes are adjusted during
configuration with a possibility of changing the text in the
control text message.
*
ON / OFF bistable mode
- change of the CH1 or CH2 output status to the opposite.
*
TIME time mode
- change of the CH1 or CH2 output status to the opposite and appropriately through time t1 for CH1 output and time
t2 for CH2 output.
*
GATE gate mode
- change of the CH1 and / or CH2 into times defined for the gate mode.
*
EXTA FREE control
- control of EXTA FREE system wireless receivers by means of RXM-01 device RXM-01 connected with the GRM-
10 device.
ADD NUM COMMAND
DEL NUM COMMAND
CONFIGURATION MODE COMMAND
CONFIGURATION MODE END COMMAND
The command adds a telephone number / numbers to the authorised list of numbers used to control CLIP (including the control in the
gate mode). 6 telephone numbers maximally can be added by one command at each time. The command refers to the local and remote
configuration.
ADD NUM
<+48tel_1> <+48tel_2>,...,<+48tel_n>
tel_1...tel_n successively entered phone numbers preceded by +48.
The maximum of numbers available n = 6.
Examples of commands:
Command
Description
ADD NUM +48602360938
48602360938 is added to the authorised list of numbers
used to control by means of CLIP calling signals.
ADD NUM+486034860048600500800
N486034860048600500800 are add-
ed to the authorised list of numbers used to control by means of
CLIP calling signals.
The command deletes a telephone number / numbers from the authorised list of numbers used to control CLIP (including the control in
the gate mode). 6 telephone numbers maximally can be deleted by one command at each time. The command refers to the local and
remote configuration.
DEL NUM
<+48tel_1> <+48tel_2>,...,<+48tel_n>
tel_1...tel_n successively entered phone numbers preceded by +48.
The maximum of numbers available n = 6.
Examples of commands:
Command
Description
DEL NUM +48602360938
48602360938 is deleted from the authorised list of num-
bers used to control by means of CLIP calling signals.
DEL NUM+486034860048600500800
N486034860048600500800 are de-
leted from the authorised list of numbers used to control by means
of CLIP calling signals.
The command makes the GRM-10 device enters from the normal operation mode into the remote configuration mode. The active com-
mand is only for the numbers included in the ADMIN list (by means of ADMIN command or the PC application). The enter into the con-
figuration mode is indicated by a flashing LED diodes LEDP1 and LEDP2.
The command allows the the GRM-10 device to go out from the configuration mode to normal operation. The active command is only
for the numbers included in the ADMIN list (by means of ADMIN command or the PC application). The command is inactive during
local configuration.