VER. 003_20.05.2011

APPEARANCE

The device is designed for 

single-phase installation and 

must be installed in accord-

ance with standards valid in a 

particular country. The device 

should be connected accord-

ing to the details included in 

this operating manual. Installation, connection 

and control should be carried out by a qualified 

electrician staff, who act in accordance with the 

service manual and the device functions. 

In case of casing dismantling an electric shock 

may occur, and the guarantee is lost then. Before  

installation make sure the connection cables are 

not under voltage. The cruciform head screwdriv-

er 3,5 mm should be used to instal the device. Im-

proper transport, storage, and use of the device 

influence its wrong functioning. It is not advisable 

to instal the device in the following cases: if any 

device part is missing or the device is damaged 

or deformed. In case of  improper functioning of 

the device contact the producer.

CAutioN!

FEAtuRES

tECHNiCAL DAtA

DESCRiPtioN

● complete  set  of  wireless  control  

(2–channel button radio transmitter 

RNK-02 and 1-channel radio flash dim-

mer RDP-01),

● lighting  operation  control  -  switch  on/

switch off, brightening and dimming,

● cooperation  with  light  bulbs,  fluores-

cent lamps powered by electronic or 

toroidal transformer,

● memory of luminous density level,

● wide range of operation (up to 180 m),

● operation is optically signalled,

● low current consumption, possibility of 

constant work,

● possibility of widening operation range 

by means of RTN-01 retransmitter.

RDP-01 dimmer cooperates with light 

bulbs,  compact  fluorescent  lamps  powe-

red by electronic or toroidal power supply 

transformers. The device has different 

functions: a traditional lighting dimmer 

function, time control functions (staircase 

time delay switch), comfort functions (me-

mory of adjusted luminous density level).

RNK-02

RDP-01

Input (supply) terminals:

-

L, N

Input rated voltage:

3 V DC (CR2032 battery)

230 V AC

Battery life:

3 ÷ 5 years

-

Input voltage tolerance:

-

-15 ÷ +10 %

Nominal frequency:

-

50 / 60 Hz

Nominal power consumption:

-

0,5 W

Number of operation modes:

-

5

Number of channels:

2

1

Transmission:

radio 868,32 MHz

Coding way:

unidirectional

Coding:

addressing transmission

Maximum number of transmitters:

-

32

Range:

up to 250 m in the open area

up to 230 m in the open area

Time adjustment:

-

1 sec ÷ 18 hours (every 1 sec.)

Optic signalling of transmitter’s operation:

LED red diode

Receiver’s output clamps:

-

, N

Maximum output load:

-

250 W

Number of terminal clamps:

-

4

Section of connecting cables:

-

do 2,5 mm

2

Ambient temperature range:

-10 ÷ +55 

o

C

Operating position:

free

Casing mounting: wall plugs, double-sided adhesive tape installation cable box Ø60 mm

Casing protection degree:

IP20 (EN 60529)

Protection level:

III

II

Overvoltage category:

II

Pollution degree:

2

Surge voltage:

-

1 kV (EN 61000-4-5)

Dimensions:

90 x 80 x 11,5 mm

47,5 x 47,5 x 20 mm

Weight:

0,038 kg

0,040 kg

Reference standard:

ETSI EN 300 220-1, 

ETSI EN 300 220-2

EN 60669, EN 60950, 

EN 61000

The symbol means selective 

collecting of electrical and electronic 

equipment.  

It is forbidden to put the used 

equipment together with other waste.

Optic signalling of receiver’s operation
Programming push-button

Receiver’s input (supply) terminals (

, N)

Input (supply) terminals (L, N)

Optic signalling of transmitter’s operation

Push-button

CoNNECtioN

APPLiCAtioN

RDP-01 MouNtiNG

1. Disconnect power supply by the phase fuse, 

the circuit-breaker or the switch-disconnector 
combined to the proper circuit.

2. Check if there is no voltage on connec-

tion cables by means of a special measure 

equipment.

3. Connect the cables with the terminals in ac-

cordance with the installing diagram.

4. Install RDP-01 device in installation cable box.  
5. Switch on the power supply from the mains.

RNK-02 FuNCtioNiNG, MouNtiNG

By pressing the button, the transmitter sends a 

signal with 868,32 MHz frequency which controls 

EXTA FREE receivers. 

Device programming 

procedure (adding a transmitter to a receiv-

er’s memory) is described in particular EXtA 

FREE

 manual instructions. The device range (up 

to 250 m depending on a receiver) can be in-

creased by means of a retransmitter or few RTN-

01 retransmitters. The device can be mounted in 

any place by means of double-sided adhesive 

tape or two wall plugs (5x(3x30) mm.

Mounting by means of wall plugs:

1. Remove the button - to do it press the button 

on one side, and on the other side put a screw-

driver into a slot and lift up the button.

2. Find a place on the wall to mount the transmit-

ter, make two holes corresponding mounting 

holes from the transmitter’s base.

3. Set wall plugs in the holes.

4. Fix the base by means of screwing screws into 

wall plugs.

5. Place the button again.

BAttERY CHANGE

Battery discharge status is signalled by sev-

eral LED red diode flashes during transmis-

sion time.

1. Remove the button (as in point 1 of mounting).

2. By means of a screwdriver lever up the printed-

circuit board releasing the bottom latch (Fig. 2), 

and remove it from the base.

3. Remove the battery from the latch.

4. Mount a new battery. 

Watch battery polari-

sation marked on the latch. Wrong battery 

mounting may cause device damage.

5. Put the removed printed-circuit board back in 

the base.

6. Put back the button.

CAutioN: 

While changing the battery, it is suggested to 

press any of the buttons for about 5 seconds 

before putting it into a latch. Next press trans-

mission button several times to check its op-

eration. if the transmitter does not work prop-

erly repeat the battery change procedure.

Radio flush dimmer RDP-01 operates as  

a receiver of 2-channel button radio  

transmitter RNK-02 (switch on/switch off 

control, lighting source brightening/dimming). 

The above mentioned transmitters  

can also control operation of radio lighting 

switch RWL-01.

CAPACitY

250W

250W

250W

250W

WARRANtY CARD

There is 24 months guarantee on the product

1.  ZAMEL provides a two-year warranty for its products. 

2.  The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances  

b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS-

TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting 

from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device 

in the moment of sale (if they appear); 

3.  All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.; 

4.  ZAMEL will review complaints in accordance with existing regulations.; 

5.  The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 

6.  Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy 

between the goods and the contract.

Salesman stamp and signature, date of sale

The ZAMEL company 

devices which are 

characterised with this sign 

can cooperate 

with each other.

Reviews: