plik: inst_ext_gb_rtm-02 | modyfikacja: 03.01.2014
MOUTING, OPERATION
APPLICATION
DIMENSIONS
PRODUCT FAMILY
The RTM-02 temperature regulator is a
member of the RTM family.
1. Disconnect the electric network by
means of an appropriate cut-off,
current-limiting circuit-breaker or
separator.
2. Check if there is no any voltage
between power leads by means of
an appropriate gauge.
3. Mount the
RTM-02
module on TH 35
rail.
4. Connect the system leads according
to the electrical diagram.
5. Connect power supply circuit.
The device is ready to work just right
after its appropriate connecting. The
system controls temperature near the
external NTC probe. When temperature
drops below T
p
- ∆T temperature, the
regulator will switch ON the output relay
(11 – 14 contacts shorted) and the relay
load (e.g. heater). The heater will be
ON until the temperature reaches T
p
+
∆T. The temperature hysteresis is about
∆T ~ 1
o
C. The hysteresis is needed for
decreasing relay switching frequency.
NTC temperature sensor connecction
signalization:
• sensor input open- green LED diode
pulses once a second,
• sensor input closed - green LED
diode pulses three times a second,
• sensor properly connected - green
LED diode illuminates constantly.
WARRANTY CARD
There is 24 months guarantee on the product
Salesman stamp and signature, date of sale
1. ZMIE ZAMEL SP. J. assures 24 months guarantee for the product.
2. The manufacturer’s guarantee does not cover any of the following actions:
a) mechanical damage during transport, loading / unloading or under other circumstances,
b) damage caused by incorrect product mounting or misuse,
c) damage caused by unauthorised modifications made by the PURCHASER or any third parties to the product or any other devices
needed for the product functioning,
d) damage caused by Act of God or any other incidents independent of the manufacturer.
3. The PURCHASER shall lay any claims in writing to the dealer or ZMIE ZAMEL SP. J.
4. ZMIE ZAMEL SP. J. is liable for processing any claim according to current Polish legislation.
5. ZMIE ZAMEL SP. J. shall process the claim at its own discretion: product repair, replacement or money return.
6. The manufacturer’s guarantee is valid in the Republic of Poland.
7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or
otherwise are not affected by this warranty.
CONNECTION
TIME DIAGRAMS
INNER DIAGRAM
Floor heating system.
heating
μC
L
N
L
N
Device version:
01 - basic
02 - extended
20 - with the LCD display
30 - extended with
the LCD display
Device type