RZB-01 WIRELESS CONTROL KIT - LIGHTING
MANUAL INSTRUCTION
ZAMEL
Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04
www.zamelcet.com
, e-mail: [email protected]
VER. 003_20.05.2011
APPEARANCE
The device is designed for
single-phase installation and
must be installed in accord-
ance with standards valid in a
particular country. The device
should be connected accord-
ing to the details included in
this operating manual. Installation, connection
and control should be carried out by a qualified
electrician staff, who act in accordance with the
service manual and the device functions.
In case of casing dismantling an electric shock
may occur, and the guarantee is lost then. Be-
fore installation make sure the connection ca-
bles are not under voltage. The cruciform head
screwdriver 3,5 mm should be used to instal the
device. Improper transport, storage, and use of
the device influence its wrong functioning. It
is not advisable to instal the device in the fol-
lowing cases: if any device part is missing or
the device is damaged or deformed. In case of
improper functioning of the device contact the
producer.
CAutioN!
FEAtuREs
tECHNiCAL DAtA
DEsCRiPtioN
● complete set of wireless control
(2–channel button radio transmitter
RNK-02 and 1-channel bistable radio
receiver ROP-01),
● light operation control and other re-
ceivers control,
● receivers are easily installed in an
electric-light fitting or in Ø60 mm junc-
tion box,
● five operation modes: switching on
mode, switching off, monostable, bi-
stable, time (switch off delay),
● wide range of operation (up to 180 m),
● operation is optically signalled,
● low current consumption, possibility of
constant work,
● possibility of widening operation range
by means of RTN-01 retransmitter.
RZB-01 set includes radio receiver
ROP-01 used in flush and surface mo-
unting and RNK-02 transmitter, battery
powered, can be mounted in any place.
The set gives comfortable solution used
to control lighting and other receivers re-
motely.
RNK-02
ROP-01
Input (supply) terminals:
-
L, N
Input rated voltage:
3 V (CR2032 battery)
230 V AC
Battery life:
3 ÷ 5 years
-
Input voltage tolerance:
-
-15 ÷ +10 %
Nominal frequency:
-
50 / 60 Hz
Nominal power consumption:
-
0,29 W
Number of operation modes:
-
5
Number of channels:
2
1
Transmission:
radio 868,32 MHz
Coding way:
unidirectional
Coding:
addressing transmission
Maximum number of transmitters:
-
32
Range:
up to 250 m in the open area
up to 230 m in the open area
Time adjustment:
-
1 s ÷ 18 hours (every 1 sec.)
Optic signalling of transmitter’s operation:
LED red diode
Relay output clamps:
-
12, 11, 14
Relay contacts parameters:
-
1NO/NC 5A / 250V~ AC1 1250 VA
Number of terminal clamps:
-
5
Section of connecting cables:
-
do 2,5 mm
2
Ambient temperature range:
-10 ÷ +55
o
C
Operating position:
free
Casing mounting: wall plugs, double-sided adhesive tape
installation cable box Ø60 mm
Casing protection degree:
IP20 (EN 60529)
Protection level:
III
II
Overvoltage category:
-
II
Pollution degree:
2
Surge voltage:
-
1 kV (EN 61000-4-5)
Dimensions:
90 x 80 x 11,5 mm
47,5 x 47,5 x 20 mm
Weight:
0,038 kg
0,043 kg
Reference standard:
ETSI EN 300 220-1
ETSI EN 300 220-2
EN 60669, EN 60950
EN 61000
The symbol means selective collecting
of electrical and electronic equipment.
It is forbidden to put the used
equipment together with other waste.
Optic signalling of receiver’s operation
Programming buttons
Relay output terminals
(12, 11, 14)
Input (supply) terminals (L, N)
Optic signalling of transmitter’s operation
Push-button
WARRANtY CARD
There is 24 months guarantee on the product
1. ZAMEL provides a two-year warranty for its products.
2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances
b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS-
TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting
from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device
in the moment of sale (if they appear);
3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.;
4. ZAMEL will review complaints in accordance with existing regulations.;
5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.
6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy
between the goods and the contract.
salesman stamp and signature, date of sale
CoNNECtioN
APPLiCAtioN
1-channel radio flush receiver ROP-01
operates as a receiver of 8-channel
remote controller P-256/8 and of
2-channel button radio transmitter
RNK-02 (light sources switch on/switch
off control). The above mentioned
transmitters can also control operation
of radio lighting switch RWL-01
and remote control socket RWG-01.
CAPACitY
750W
250W
500W
375W
MouNtiNG
1. Disconnect power supply by the phase fuse,
the circuit-breaker or the switch-disconnector
combined to the proper circuit.
2. Check if there is no voltage on connec-
tion cables by means of a special measure
equipment.
3. Connect the cables with the terminals in ac-
cordance with the installing diagram.
4. Install ROP-01 device in installation cable
box.
5. Switch on the power supply from the mains.
RNK-02 FuNCtioNiNG, MouNtiNG
By pressing the button, the transmitter sends
a signal with 868,32 MHz frequency which con-
trols EXTA FREE receivers.
Device program-
ming procedure (adding a transmitter to
a receiver’s memory) is described in par-
ticular EXtA FREE manual instructions.
The device range (up to 250 m depending on
a receiver) can be increased by means of a re-
transmitter or few RTN-01 retransmitters. The
device can be mounted in any place by means
of double-sided adhesive tape or wall plugs
5 x (3 x 30) mm.
Mounting by means of wall plugs:
1. Remove the button - to do it press the but-
ton on one side, and on the other side put
a screwdriver into a slot and lift up the button.
2. Find a place on the wall to mount the transmit-
ter, make two holes corresponding mounting
holes from the transmitter’s base.
3. Set wall plugs in the holes.
4. Fix the base by means of screwing screws
into wall plugs.
5. Place the button again.
BAttERY CHANGE
Battery discharge status is signalled by sev-
eral LED red diode flashes during transmis-
sion time.
1. Remove the button (as in point 1 of mounting).
2. By means of a screwdriver lever up the
printed-circuit board releasing the bottom latch
(Fig. 2), and remove it from the base.
3. Remove the battery from the latch.
4. Mount a new battery.
Watch battery polari-
sation marked on the latch. Wrong battery
mounting may cause device damage.
5. Put the removed printed-circuit board back in
the base.
6. Put back the button.
CAutioN: While changing the battery,
it is suggested to press any of the buttons
for about 5 seconds before putting it into
a latch. Next press transmission button sev-
eral times to check its operation. if the trans-
mitter does not work properly repeat the bat-
tery change procedure.
The ZAMEL company
devices which are
characterised with this sign
can cooperate
with each other.