ASN - 02 STAIRCASE TIMER
INSTRUCTION MANUAL
Zakład Mechaniki i Elektroniki
ZAMEL
sp.j.
J.W. Dzida, K. Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com,
e-mail:
APPERANCE
FEATURES
TECHNICAL DATA
DESCRIPTION
ی Staircase lighting control,
ی Continuous on-time adjustment of 10
seconds to 14 minutes,
ی Relay state indicator red LED,
ی Applicable together with single pole
push buttons, illuminated,
ی Counter-interlock function,
ی Either three-conductor or four-con
-
ductor wiring system possible,
ی Surface-mounted casing,
ی Relay voltage output, maximum load
16 A.
The ASN-02 staircase timer is desig
-
ned for corridor and staircase lighting con
-
trol. After circuit triggering the timer keeps
the light ON for the preset time and then
switches it OFF. It has an adjustable ON-
time setting of 10 seconds to 14 minutes.
ON-time may be adjusted by means of a
potentiometer placed on the timer front
panel.
The timer is fitted with a counter-
interlock circuit
. The ASN-02 staircase
timer may by applied as a time relay for
delayed switch OFF. The device is placed
within a surface-mounted casing and may
be mounted onto the flat surfaces.
The device should be
connected to a single-
phase system accordin
-
gly to current standards.
The device connection
swill be described in this
manual. Only qualified
electricians are allowed to connect,
assembly and adjust the timer. It is ne
-
cessary to read this manual before the
timer mounting. Do not disassembly the
timer casing or you will lose any war
-
ranty rights and expose yourself to the
electric shock hazard. Before mounting
operation make sure of disconnecting
the connection wires from the electric
network. Use a cross-head screwdriver
of 3.5 mm diameter to mount the devi
-
ce. The timer should be carried, stored
and used in an appropriate way. Do not
mount the timer in case of any device
parts lack, damage or deformation. In
case of malfunction please notify the
manufacturer.
CAUTION
ASN - 02
Power terminals:
L, N
Rated voltage: 230 V~
Rated voltage tolerance: -15 ÷ +10 %
Rated frequency: 50 / 60 Hz
Rated current: 33 mA
Trigger terminal:
IN
Load power terminal: P
Relay state indicator:
red LED
ON-time adjustment range: 10 s ÷ 14 min
ON-time setting accuracy: ±10 %
ON-time setting repeatability: ±5 %
ON-time setting: continuous (potentiometer)
Relay contacts parameters: 1NO-16 A / 250 V AC1 4000 VA (voltage contact)
Connection terminals quantity: 4
Connection wire section: 0,2 ÷ 2,50 mm
2
Operating temperature: -20 ÷ +45
o
C
Operating position: optional
Casing fastening: 5x(3x20) strut pins, 2 pieces
Casing IP: IP20 (PN-EN 60529)
Protection class:
II
Overvoltage category:
II
Pollution level:
2
Dimensions: 69x56x27 mm
Weight: 67 g
Standard conformity: PN-EN 60669-1
PN-EN 60669-2-1
PN-EN 61000-4-2,3,4,5,6,11
ON-time adjust potentiometer
Relay state indicator
Load power terminal (P)
Power terminals (N, L)
Timer trigger terminal (IN)