background image

  ASN - 02 STAIRCASE TIMER 

INSTRUCTION MANUAL 

Zakład Mechaniki i Elektroniki 

ZAMEL 

sp.j.

J.W. Dzida, K. Łodzińska

ul. Zielona 27, 43-200 Pszczyna, Poland

Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04

www.zamelcet.com, 

e-mail:

 [email protected]

APPERANCE

FEATURES

TECHNICAL DATA

DESCRIPTION

ی  Staircase lighting control,

ی  Continuous on-time adjustment of 10 

seconds to 14 minutes,

ی  Relay state indicator red LED,

ی  Applicable  together  with  single  pole 

push buttons, illuminated,

ی  Counter-interlock function,

ی  Either  three-conductor  or  four-con

-

ductor wiring system possible,

ی  Surface-mounted casing,

ی  Relay voltage output, maximum load 

16 A.

The ASN-02 staircase timer is desig

-

ned for corridor and staircase lighting con

-

trol. After circuit triggering the timer keeps 

the light ON for the preset time and then 

switches it OFF. It has an adjustable ON-

time setting of 10 seconds to 14 minutes. 

ON-time may be adjusted by means of a 

potentiometer  placed  on  the  timer  front 

panel. 

The timer is fitted with a counter-

interlock  circuit

.  The  ASN-02  staircase 

timer  may  by  applied  as  a  time  relay  for 

delayed switch OFF. The device is placed 

within a surface-mounted casing and may 

be mounted onto the flat surfaces.

The  device  should  be 

connected  to  a  single-

phase  system  accordin

-

gly to current standards. 

The  device  connection 

swill be described in this 

manual.  Only  qualified 

electricians  are  allowed    to  connect, 

assembly and adjust the timer. It is ne

-

cessary to read this manual before the 

timer mounting. Do not disassembly the 

timer  casing  or  you  will  lose  any  war

-

ranty rights and expose yourself to the 

electric shock hazard. Before mounting 

operation  make  sure  of  disconnecting 

the connection wires  from the electric 

network.  Use a cross-head screwdriver 

of 3.5 mm diameter to mount the devi

-

ce. The timer should be carried, stored 

and used in an appropriate way. Do not 

mount  the  timer  in  case  of  any  device 

parts  lack,  damage  or  deformation.  In 

case  of  malfunction  please  notify  the 

manufacturer.

CAUTION

ASN - 02

Power terminals:

L, N

Rated voltage: 230 V~

Rated voltage tolerance: -15 ÷ +10 %

Rated frequency: 50 / 60 Hz

Rated current:  33 mA

Trigger terminal:

IN

Load power terminal: P
Relay state indicator:

red LED

ON-time adjustment range: 10 s ÷ 14 min

ON-time setting accuracy: ±10 %

ON-time setting repeatability: ±5 %

ON-time setting: continuous (potentiometer)

Relay contacts parameters: 1NO-16 A / 250 V AC1 4000 VA (voltage contact)

Connection terminals quantity: 4

Connection wire section: 0,2 ÷ 2,50 mm

Operating temperature: -20 ÷ +45 

o

C

Operating position: optional

Casing fastening: 5x(3x20) strut pins, 2 pieces

Casing IP: IP20 (PN-EN 60529)

Protection class:

II

Overvoltage category:

II

Pollution level:

2

Dimensions: 69x56x27 mm

Weight: 67 g

Standard conformity: PN-EN 60669-1

PN-EN 60669-2-1

PN-EN 61000-4-2,3,4,5,6,11

ON-time adjust potentiometer

Relay state indicator

Load power terminal (P)
Power terminals (N, L)

Timer trigger terminal  (IN)

Reviews: