Switch Bank 2
Upper Boom Control (OFF-ON)
•
This switch controls water flow to the upper boom.
•
Operation:
-
Left LED is illuminated
Red
when in the
OFF
position
-
Right LED is illuminated
White
when the in the
ON
position
Lower Boom Control (OFF-ON)
•
This switch controls water flow to the lower boom.
•
Operation
-
Left LED is illuminated
Red
when in the
OFF
position
-
Right LED is illuminated
White
when the in the
ON
position
Application Rate Scaling (DEC)-HOLD-(INC)
•
This function allows the operator to increase or decrease a scaling factor applied to the default
value of 100%, and allows for situations where a lesser or greater water application rate is
desirable.
•
Operation:
-
Off when in the HOLD position
-
Blinks
Blue
once for each single press of
DEC
(decrement) on the left of the switch
-
Blinks
Green
once for each single press of
INC
(increment) on the right of the
switch
-
Each press of either DEC-INC switch will generate one blink for each press of the
switch.
-
Each press of the switch will change the spray flow 5 percentage points to a
maximum of 50% (10 presses). The switch will only blink when pushed.
Board Spray (OFF-ON)
•
This switch controls water flow out of the Board Spray Valve.