3. Speciications

1) ZM500-GT Electrical & Physical Speciications

2) ZM500-GT Cable Speciications

AC Input Range

Voltage

100 ~ 240VAC

V

out

Output Load Rating Combined

Combined Power

Frequency 

50 ~ 60

I

min

I

max

I

peak

AC Input Current

100VAC

7.5A

+3.3V

0.1A

24A

123W

500W

240VAC

4A

+5V

0.2A

24A

PFC Type

Active PFC

+12V1

0.1A

18A

19A

432W

Power Factor

MAX 99%

+12V2

0.5A

18A

19A

Inrush Current Limit

(@ Cold start at 25

)

115VAC

MAX 70A

-12V

0.0A

0.5A

6W

230VAC

MAX 150A

+5VSB

0.0A

2.5A

3.0A

12.5W

Eficiency

MAX 87% @ 230VAC, Typical load

Ambient Temperature

DC Output Voltage 

Regulation

V

out

Stable Range

At 

Full

Load

Operation

0 ~ +40

+3.3VDC

±5%

+3.14 ~ +3.47V

Stored

-20 ~ +80

+5VDC

±5%

+4.75 ~ +5.25V

Ambient Humidity

+12V1DC

±5%

+11.4 ~ +12.6V

Operation

5 ~ 95% RH

+12V2DC

±5%

+11.4 ~ +12.6V

Stored

5 ~ 95% RH

-12VDC

±10%

-10.8 ~ -13.0V

Dimensions

140(L)   150(W)   86(H)

+5VSB

±5%

+4.75 ~ +5.25V

Weight

2.17Kg (Full Package)

DC Output Ripple & 

Noise

V

out

Standard Range

At 

Full

Load

Safety Features

+3.3VDC

50mV

Over-Voltage Protection (OVP)

+5VDC

50mV

Under-Voltage Protection (UVP)

+12V1DC

120mV

Over-Current Protection (OCP)

+12V2DC

120mV

Short-Circuit Protection (SCP)

-12VDC

120mV

Over-Power Protection (OPP)

+5VSB

50mV

PCI Express2
Power Connector

PCI Express1
Power Connector

Mainboard Power

Connector

CPU Power
Connector

S-ATA Power
Connector

S-ATA Power
Connector

ODD/HDD Power
Connector

ODD/HDD Power
Connector

ODD/HDD Power
Connector

ODD/HDD Power
Connector

FDD Power
Connector

Summary of Contents for ZM500-GT

Page 1: ...User s Manual ZM500 600 700 GT Ver 1 0 www ZALMAN com To ensure safe and easy installation please read the following precautions Two Forward Switching Power Supply ...

Page 2: ...ower source may cause damage to the motherboard Make sure that the connectors are connected to their designated locations and that the connectors are not oriented in the wrong direction when connecting the DC output connectors Please use gloves to prevent injuries during installation Product designs and speciications may be revised without prior notiication to improve quality and performance Negle...

Page 3: ... Operation 0 40 3 3VDC 5 3 14 3 47V Stored 20 80 5VDC 5 4 75 5 25V Ambient Humidity 12V1DC 5 11 4 12 6V Operation 5 95 RH 12V2DC 5 11 4 12 6V Stored 5 95 RH 12VDC 10 10 8 13 0V Dimensions 140 L 150 W 86 H 5VSB 5 4 75 5 25V Weight 2 17Kg Full Package DC Output Ripple Noise Vout Standard Range At Full Load Safety Features 3 3VDC 50mV Over Voltage Protection OVP 5VDC 50mV Under Voltage Protection UVP...

Page 4: ... 40 12V1DC 5 11 4 12 6V Stored 20 80 12V2DC 5 11 4 12 6V Ambient Humidity 12V3DC 5 11 4 12 6V Operation 5 95 RH 12V4DC 5 11 4 12 6V Stored 5 95 RH 12VDC 10 10 8 13 0V Dimensions 5VSB 5 4 75 5 25V 140 L 150 W 86 H DC Output Ripple Noise Vout Standard Range At Full Load Weight 3 3VDC 50mV 2 46Kg Full Package 5VDC 50mV Safety Features 12V1DC 120mV Over Voltage Protection OVP 12V2DC 120mV Under Voltag...

Page 5: ...1 4 12 6V Stored 20 80 12V2DC 5 11 4 12 6V Ambient Humidity 12V3DC 5 11 4 12 6V Operation 5 95 RH 12V4DC 5 11 4 12 6V Stored 5 95 RH 12VDC 10 10 8 13 0V Dimensions 5VSB 5 4 75 5 25V 140 L 150 W 86 H DC Output Ripple Noise Vout Standard Range At Full Load Weight 3 3VDC 50mV 2 50Kg Full Package 5VDC 50mV Safety Features 12V1DC 120mV Over Voltage Protection OVP 12V2DC 120mV Under Voltage Protection U...

Page 6: ...5 5 4 Certiications E198072 ...